Sierra Monitor Corporation IZS31 Alarm, Timing chart „ Timing chart with a normal operation

Page 16

9. Alarm

Type of alarm

Description

Abnormal high voltage

Notifies when overcurrent such as high voltage

 

leakage occurs. The ion-discharge-output is

 

stopped, HV ALRM sets off and output the

 

signal for failure.

Sensor failure

Notifies that the feed back sensor doesn’t work

 

properly. SNSR ALARM lights up, and the

 

signal for sensor failure is output.

CPU failure

Notifies that CPU fails due to noise. All LEDs

 

Flashes, and the signal for CPU failure is

 

output.

Electrode needle

Notifies when the maintenance of the electrode

maintenance

needle is necessary. NDL CHECK ALARM

 

lights up, and the maintenance output signal is

 

output.

How to reset

Turn off the power supply to solve the problem. Once it’s solved, apply the power supply again. Or turn on and off the discharge-stop signal.

Turn off the power supply to solve the problem. Once it’s solved, apply the power supply again. Or turn on and off the discharge-stop signal.

Turn off the power supply to solve the problem. Once it’s solved, apply the power supply again. Or turn on and off the discharge-stop signal.

Turn off the power supply and clean the electrode needle. Then apply the power supply.

10.Timing chart

„Timing chart with a normal operation

Charged condition of the work

30V

 

 

0V

 

 

ON

Power supply DC24V

Input

OFF

 

 

Discharge-stop signal

 

ON (Opration)

Input

OFF

Completion signal for

 

ON (discharge)

Output

 

static charge elimination

OFF

 

 

 

 

ON (Output)

Sensor monitor output

Output

OFF

Charged condition

 

ON (LED)

LED

 

(with ION LED)

OFF

 

 

„Timing chart when the dirt on the electrode needle is detected

Power supply

 

ON

 

 

 

 

 

 

 

 

Input

OFF

 

 

 

 

 

 

 

 

DC24V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Discharge stop

 

ON

(Operation)

 

 

 

 

 

 

signal

Input

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Completion signal for

 

ON

(discharge)

Contamination detecting of electrode

Output OFF

 

 

 

 

 

 

2s

 

Static charge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance

 

ON

(SW ON)

100ms or more

Input

OFF

 

 

 

 

 

 

 

 

start-up signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance

 

ON

(SW ON)

 

 

 

 

 

 

output signal

Output OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance indication

ON

(LED)

 

 

 

Blink

 

LED

OFF

 

 

 

 

 

 

 

 

(With NDL CHECK ALARM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON and OFF status will be changed depending on the situation

The completion signal for static charge elimination is output while the dirt on the electrode needle is being detected

Because ions are discharged from the ionizer when the electrode needle is being detected, the workpiece might be charged. Therefore, the workpieces should not be mounted when the detection is executed.

15

Image 16
Contents IZS31 Series Doc. No.IZ*-OMK0015 BInstallation of Ionizer body ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Safety instructions Installation To 1.5 NmWiring and piping Environment Installation of Ionizer body InstallationAttached M4 threads Intermediate bracket M5 threadsInstallation of sensor head Installation of sensorM3 screws Metal plate Operation mode Function descriptionSee the selection of models and setting Detection of the dirt on the electrode needle.Selection and setting of equipment .Sensing DC mode„ Connection with the power supply for I/O signal OUT4„ Alarm LED ・・・ Failure of the ionizer is displayed „ ION LED ・・・ The charged condition of the work is displayedAlarm Timing chart „ Timing chart with a normal operationPulse DC mode Auto ManualPower supply cable for „ Connection power supply for I/O signalFunction Ionizer drive„ Alarm LED ・・・ Failure of the ionizer will be indicated Goes out② Auto operation (b)W/o auto balance sensor.DC mode „ ION LED ・・・ The discharged ion polarity is displayed Power supply cable connection circuit PNP .Specifications [Electrode cartridge quantity and weight].Ionizer 300 380 620 780 1100 1260 1500 1900 2300.Sensor „ Sensor monitor output When feed back sensor is used„ Detection range of Feedback sensor