Sierra Monitor Corporation IZS31 „ ION LED ・・・ The discharged ion polarity is displayed

Page 22

6.LED display

„POWER LED ・・・ The power supply input and the connection of the sensors are displayed.

LED name

 

Functions

POWER

MAIN

Lights up when the power supply is applied. (Green)

 

 

(Flashes when wrong power supply is applied.

 

SNSR

Goes out.

„ION LED ・・・ The discharged ion polarity is displayed.

LED name

 

Functions

ION

Lights on when plus ions are generated.(Orange)

 

OK

Goes out.

 

Lights on when minus ions are generated.Blue

„ALARM LED ・・・ Failure of the ionizer is displayed.

LED name

 

Functions

ALARM

HV

Lights up when overcurrent is applied to the electrode needle. Red

 

SNSR

Goes out.

 

NDL

Goes out.

 

CHECK

 

7. Alarm

Type of alarm

Description

Abnormal high voltage

Notifies when overcurrent such as high voltage

 

leakage occurs. The ion-discharge-output is

 

stopped, HV ALRM sets off and output the

 

signal for failure.

CPU failure

Notifies that CPU fails due to noise. All LEDs

 

Flashes, and the signal for CPU failure is

 

output.

How to reset

Turn off the power supply to solve the problem. Once it’s solved, apply the power supply again. Or turn on and off the discharge-stop signal.

Turn off the power supply to solve the problem. Once it’s solved, apply the power supply again. Or turn on and off the discharge-stop signal.

8.Timing chart

„Timing chart with a normal operation

 

 

ON

 

 

 

 

Power supply DC24V

Input

OFF

 

 

 

 

 

 

 

 

 

 

 

 

ON

(Operation)

 

 

Discharge-stop signal

Input

OFF

 

 

 

 

 

 

 

 

 

 

 

 

ON

(Discharge)

 

 

State of ion discharge

 

OFF

 

 

 

 

 

 

 

 

 

 

 

21

Image 22
Contents IZS31 Series Doc. No.IZ*-OMK0015 BInstallation of Ionizer body ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Safety instructions Installation To 1.5 NmWiring and piping Environment Installation of Ionizer body InstallationAttached M4 threads Intermediate bracket M5 threadsInstallation of sensor head Installation of sensorM3 screws Metal plate Operation mode Function descriptionSee the selection of models and setting Detection of the dirt on the electrode needle.Selection and setting of equipment .Sensing DC mode„ Connection with the power supply for I/O signal OUT4„ Alarm LED ・・・ Failure of the ionizer is displayed „ ION LED ・・・ The charged condition of the work is displayedAlarm Timing chart „ Timing chart with a normal operationPulse DC mode Auto ManualFunction Power supply cable for„ Connection power supply for I/O signal Ionizer drive„ Alarm LED ・・・ Failure of the ionizer will be indicated Goes out② Auto operation (b)W/o auto balance sensor.DC mode „ ION LED ・・・ The discharged ion polarity is displayed Power supply cable connection circuit PNP .Ionizer .Specifications[Electrode cartridge quantity and weight] 300 380 620 780 1100 1260 1500 1900 2300.Sensor „ Sensor monitor output When feed back sensor is used„ Detection range of Feedback sensor