Sierra Monitor Corporation IZS31 operation manual Safety instructions

Page 3

1. Safety instructions

These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard by labeling "Caution", "Warning", and "Danger". To ensure safety, be sure to observe ISO4414, JIS B8370and other safety precautions.

!

CAUTION

Operator error could result in injury or equipment damage.

!

WARNING

Operator error could result in serious injury or loss of life.

!

DANGER

In extreme conditions, there is a possibility of serious injury or loss of life.

1) ISO 4414 : Pneumatic fluid power –Recommendation for application of equipment to transmission and control systems

2) JIS B 8370 : Rule for Pneumatic System

!WARNING

1.The compatibility of equipment is the responsibility of the person who designs the system or decides its specifications.

Since the products specified here are used in various operating conditions, their compatibility with the specific system must be based on specifications or after analysis and/or tests to meet your specific requirements. Those who decide the compatibility of equipment shall take the responsibility to guarantee the initial system performance and safety. Construct system as reviewing all specifications in the latest catalog or documents as well as considering the possibility of equipment in every occasion.

2. Only trained personnel should operate machinery and equipment.

This product generates high voltage, so it can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of systems should be performed by trained and experienced operators.

3.Do not service machinery/equipment or attempt to eliminate components until safety is confirmed.

1)Inspection and maintenance of the machinery and equipment should be performed after confirmation of the safety such as earthing, prevention of electric shock and each type of injury.

2)When equipment is to be eliminated, confirm the safety process as mentioned above. Cut air pressure supply and electric power supply that are the energy source for the equipment, and exhaust all residual compressed air in the system.

3)Before machinery/equipment is re-started, take measures to prevent short circuit etc. with enough care.

4.Do not use product under the following conditions or environments. If it is not avoidable, take appropriate measures and contact SMC.

1)Conditions and environments beyond specifications or if product is used outdoors.

2)Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverage, recreation equipment , emergency stop circuits, pressing clutch, break circuit and safety equipment.

3)An application which has the possibility of having negative effects on people, property, or animals requiring special safety analysis.

2

Image 3
Contents Doc. No.IZ*-OMK0015 B IZS31 SeriesInstallation of Ionizer body ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Safety instructions To 1.5 Nm InstallationWiring and piping Environment Installation Installation of Ionizer bodyAttached M4 threads M5 threads Intermediate bracketInstallation of sensor Installation of sensor headM3 screws Metal plate Function description Operation modeDetection of the dirt on the electrode needle See the selection of models and setting.Sensing DC mode .Selection and setting of equipmentOUT4 „ Connection with the power supply for I/O signal„ ION LED ・・・ The charged condition of the work is displayed „ Alarm LED ・・・ Failure of the ionizer is displayedTiming chart „ Timing chart with a normal operation AlarmAuto Manual Pulse DC modeIonizer drive Power supply cable for„ Connection power supply for I/O signal FunctionGoes out „ Alarm LED ・・・ Failure of the ionizer will be indicated(b)W/o auto balance sensor ② Auto operation.DC mode „ ION LED ・・・ The discharged ion polarity is displayed Power supply cable connection circuit PNP 300 380 620 780 1100 1260 1500 1900 2300 .Specifications[Electrode cartridge quantity and weight] .Ionizer„ Sensor monitor output When feed back sensor is used .Sensor„ Detection range of Feedback sensor