Sierra Monitor Corporation IZS31 „ Alarm LED ・・・ Failure of the ionizer will be indicated

Page 19

8.LED display

„POWER LED ・・・ The power supply input and the connection of the sensors are displayed.

LED name

 

Functions

POWER

MAIN

Lights up when the power supply is applied. (Green)

 

 

(Flashes when wrong power supply is applied.

 

SNSR

Lights up when the auto balance sensor is connected.(Green)

„ ION LED ・・・ The discharged ion polarity and ion balance are displayed.

LED name

 

Function

 

ION

Lights on when plus ions are generated.(Orange)

 

 

OK

With auto balance sensorCondition of the ion balance

Green

 

 

W/o auto balance sensorGoes out

 

 

Lights on when minus ions are generated.(Blue)

 

The ion balance state can be identified with the LED display.

Ion balance

OK LED

Below +/-30V

Lighet up.(or flashes)

+/-30V or more

Goes out

LED [OK] flashes when the ion balance nears the limit of the adjustment of the ion balance and indicates that it is time for maintenance of the electrode needle.

„ALARM LED ・・・ Failure of the ionizer will be indicated.

LED name

 

Functions

ALARM

HV

Lights up when overcurrent is applied to the electrode

 

 

needle.Red

 

SNSR

Lights up when the auto balance sensor doesn’t work properly.Red

 

NDL

Lights up when dirt on the electrode needle is detected. Red

 

CHECK

Flashes when the dirt is being detected.

18

Image 19
Contents Doc. No.IZ*-OMK0015 B IZS31 SeriesInstallation of Ionizer body ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Safety instructions To 1.5 Nm InstallationWiring and piping Environment Installation of Ionizer body InstallationAttached M4 threads M5 threads Intermediate bracketInstallation of sensor head Installation of sensorM3 screws Metal plate Function description Operation modeDetection of the dirt on the electrode needle See the selection of models and setting.Sensing DC mode .Selection and setting of equipmentOUT4 „ Connection with the power supply for I/O signal„ ION LED ・・・ The charged condition of the work is displayed „ Alarm LED ・・・ Failure of the ionizer is displayedTiming chart „ Timing chart with a normal operation AlarmAuto Manual Pulse DC modeIonizer drive Power supply cable for„ Connection power supply for I/O signal FunctionGoes out „ Alarm LED ・・・ Failure of the ionizer will be indicated(b)W/o auto balance sensor ② Auto operation.DC mode „ ION LED ・・・ The discharged ion polarity is displayed Power supply cable connection circuit PNP 300 380 620 780 1100 1260 1500 1900 2300 .Specifications[Electrode cartridge quantity and weight] .Ionizer.Sensor „ Sensor monitor output When feed back sensor is used„ Detection range of Feedback sensor