Bacharach H25-IR manual Standard Probe with LED and Programmable Pushbutton

Page 12

Introduction

H25-IR

 

 

1.7.4 Standard Probe

FLEXIBLE PROBE TUBE 8 or 15 inches

(200 or 381 mm)

PROBE TIP with FILTER

HOSE

6 or 12 foot

(1.8 or 3.7 m)

PROBE CONNECTOR (Align with red dot on instrument’s front panel PROBE receptacle)

1.7.5 Standard Probe with LED and Programmable Pushbutton

HOSE

6 or 12 foot

(1.8 or 3.7 m)

FLEXIBLE PROBE TUBE 8 or 15 inches

(200 or 381 mm)

 

 

 

PROBE TIP with FILTER

 

 

 

 

 

 

 

 

PROGRAMMABLE PUSHBUTTON

 

LED

(Can be programmed to either zero

 

(Flash rate increases as

the instrument, or switch between

 

the detected gas level

the Search and Measure mode of

 

increases, or lights

operation)

 

steady when a user

 

 

 

selected leak rate is

 

 

 

 

 

 

detected.)

PROBE CONNECTOR

 

 

 

 

 

(Align with red dot on

 

 

instrument’s front panel

 

 

PROBE receptacle)

 

 

 

 

 

 

8

Instruction 3015-4342

Image 12
Contents H25-IR Infrared Refrigerant Gas Leak DetectorWarranty Register Your Warranty by VisitingTable of Contents Parts and Service Safety Precautions Hazard SymbolsAC Power and Grounding IntroductionCleaning Explosive AtmosphereWorking Inside the Instrument Misuse and Modifications to Instrument Case of MalfunctionOrdering Information Unpacking and Initial ChecksFeatures and Capabilities Functional Overview Leak Rate = Flow Rate x Gas ConcentrationNames and Functions of Components Front ViewRear View Interior Standard Probe Standard Probe with LED and Programmable PushbuttonSmart Probe Smart Probe Keylock Function Menu System System MenuConnecting the Probe Connecting the AC Power CordPreparing for Operation Turning on the InstrumentSystem Setup Main Menu System Setup MenuGas Type Leak UnitsRelays 4 4-20 mA LoopPchk Mode Reset DefaultsBrightness ClockConfiguring the Setups Function Setup NameRange Feedback Mode SetpointCalibration Search Auto ZeroTypical Relay 1 Wiring External Relay ConnectionsMA Current Loop Connector 4-40 mA Current Loop ConnectionPreparing for Operation H25-IR Calibration Selecting Internal or External CalibrationInternal Calibration Selection Calibration Data MenuExternal Calibration Selection and Setup CAL Internal CalibrationExternal Calibration Procedure CAL FactorMaterial Required Improving PPM Measurement Accuracy using the CAL Factor Adjusting the CAL Factor Restoring Factory CalibrationCalibration H25-IR Using the H25-IR PowerInitial Setup OperationSetup Selection Range SelectionVolume Adjustment Searching for a LeakMeasuring the Leak Rate Measuring the PPM LevelLogging Measured Readings Working with Logged MeasurementsLog Menu Clearing the Log What to Do when a Fault Occurs What is PCHK?Diagnostics Menu RS-232 CommunicationOperation H25-IR Maintenance Diagnostics MenuSensor Data Last Fault Factory Menu IR EmitterPressure Factory Factory MenuAuto Gain Leak RateLeak Gas Leak TempLeak Tempco Sensor CalModel Select Probe TypeFirmware Flashing Memory Items RequiredSelect Setup Communications Select File Load Flash Image Part Replacement Removing the Top CoverFuse Replacement Probe Tip Filter & O-Ring ReplacementInternal Filter Replacement Parts and Service Replacement PartsService Centers United StatesSpecifications CFCs, HCFCs, HFCs and HalogensSpecifications H25-IR Appendix a Factory Defaults ContinuousAppendix a H25-IR H25-IR Appendix a Headquarters Hunt Valley Circle, New Kensington, PA