Bacharach H25-IR manual Clearing the Log

Page 38

Operation

H25-IR

 

 

4.2.10.2 Clearing the Log

Display the Log menu as described Section 4.2.10. Next, use the Up and Down buttons to highlight “CLEAR LOG” and then press the ENT button to display the Clear Log screen.

CLEAR LOG

HIT ENTER TO CONFIRM

Press the ENT button to clear the log of all stored measurements.

CLEAR LOG

CLEARING LOG DATA.

4.2.10.3 Viewing the Total of all Logged Measurements

The ability to display the total of all logged measurements (up to 50) is useful in situations where it is necessary to test an installation or piece of equipment that has a maximum permissible total leak rate. For example, a halogen fire suppression system can have leaks, but the combined leak rate or the sum of all the leaks cannot exceed a certain level, which is typically specified as a fraction of the total charge per year.

To display the total of all logged measurements, first display the Log menu as described Section 4.2.10. Next, use the Up and Down buttons to highlight “LOG TOTAL” and then press the ENT button to display the Log Total screen. Note that the display is auto ranging, causing the decimal point to turn off above the value 99.9. In the example below, the total of all logged measurements is 78.5 Oz/yr.

LOG TOTAL

COMBINED LEAK RATE = 78.5 Oz/yr

4.2.10.4 Setting the Log Limit

The ability to set a log limit is useful when using the H-25IR to log the leak rate of a system that has a maximum permissible total leak rate. A relay can be programmed to energize when the total of all logged measurements (up to 50) equals the log limit (refer to Section 2.4.3 Relays).

To set the log limit, first display the Log menu as described in Section 4.2.10. Next, use the Up and Down buttons to highlight “LOG LIMIT” and then press the ENT button to display the Log Limit screen. Use the Left and Right buttons to move the blinking cursor across the screen to highlight the digit to be modified, and then use the Up and Down buttons to modify that digit. Press ENT to save the log limit value and return to the Log menu.

LOG LIMIT

IS 999.00 Oz/yr

34

Instruction 3015-4342

Image 38
Contents H25-IR Infrared Refrigerant Gas Leak DetectorWarranty Register Your Warranty by VisitingTable of Contents Parts and Service AC Power and Grounding Safety PrecautionsHazard Symbols IntroductionWorking Inside the Instrument CleaningExplosive Atmosphere Misuse and Modifications to Instrument Case of MalfunctionOrdering Information Unpacking and Initial ChecksFeatures and Capabilities Functional Overview Leak Rate = Flow Rate x Gas ConcentrationNames and Functions of Components Front ViewRear View Interior Standard Probe Standard Probe with LED and Programmable PushbuttonSmart Probe Smart Probe Keylock Function Menu System System MenuPreparing for Operation Connecting the ProbeConnecting the AC Power Cord Turning on the InstrumentGas Type System SetupMain Menu System Setup Menu Leak UnitsRelays 4 4-20 mA LoopBrightness Pchk ModeReset Defaults ClockRange Configuring the Setups FunctionSetup Name Feedback Mode SetpointCalibration Search Auto ZeroTypical Relay 1 Wiring External Relay ConnectionsMA Current Loop Connector 4-40 mA Current Loop ConnectionPreparing for Operation H25-IR Internal Calibration Selection CalibrationSelecting Internal or External Calibration Calibration Data MenuExternal Calibration Selection and Setup CAL Internal CalibrationExternal Calibration Material Required ProcedureCAL Factor Improving PPM Measurement Accuracy using the CAL Factor Adjusting the CAL Factor Restoring Factory CalibrationCalibration H25-IR Initial Setup Using the H25-IRPower OperationSetup Selection Range SelectionVolume Adjustment Searching for a LeakMeasuring the Leak Rate Measuring the PPM LevelLog Menu Logging Measured ReadingsWorking with Logged Measurements Clearing the Log Diagnostics Menu What to Do when a Fault OccursWhat is PCHK? RS-232 CommunicationOperation H25-IR Sensor Data MaintenanceDiagnostics Menu Last Fault Pressure Factory MenuIR Emitter Factory Factory MenuLeak Gas Auto GainLeak Rate Leak TempLeak Tempco Sensor CalFirmware Model SelectProbe Type Flashing Memory Items RequiredSelect Setup Communications Select File Load Flash Image Part Replacement Removing the Top CoverFuse Replacement Probe Tip Filter & O-Ring ReplacementInternal Filter Replacement Parts and Service Replacement PartsService Centers United StatesSpecifications CFCs, HCFCs, HFCs and HalogensSpecifications H25-IR Appendix a Factory Defaults ContinuousAppendix a H25-IR H25-IR Appendix a Headquarters Hunt Valley Circle, New Kensington, PA