Bacharach H25-IR manual Parts and Service, Replacement Parts

Page 53

H25-IR

Parts & Service

 

 

6 Parts and Service

6.1 Replacement Parts

Item Description

Part Number

Complete Instrument

Refer to Section 1.3

 

Ordering Information

H25-IR Unit:

 

CFC, HCFC, HFC & Halogen gases

3015-4348

R600a

3015-4464

SF6

3015-4477

CO2

3015-4473

R227

3015-4466

Standard Probe Assembly:

 

6 ft (1.8 m) hose

3015-4635

12 ft (3.7 m) hose

3015-4636

Standard Probe w/ pushbutton and LED Assembly:

 

6 ft (1.8 m) hose

3015-4639

12 ft (3.7 m) hose

3015-4640

Smart Probe w/ pushbuttons and LCD Assembly:

 

6 ft (1.8 m) hose

19-7113

12 ft (3.7 m) hose

19-7114

Flexible Probe Tube Assembly:

 

8 in. (203 mm)

3015-4666

15 in. (381 mm)

3015-4633

Filters:

 

Located in probe tip:

 

Pack of 10

3015-4515

Pack of 50

3015-4516

Located inside instrument

3015-4415

Probe Tip

3015-4629

O-Ring, Probe Tube

3015-2664

Bezel, Case

3015-4670

AC Power Cord

304-3459

Fuse, 1A

604-2610

Instruction 3015-4342

49

Image 53
Contents Infrared Refrigerant Gas Leak Detector H25-IRRegister Your Warranty by Visiting WarrantyTable of Contents Parts and Service Hazard Symbols Safety PrecautionsAC Power and Grounding IntroductionExplosive Atmosphere CleaningWorking Inside the Instrument Misuse and Modifications to Instrument Case of MalfunctionUnpacking and Initial Checks Ordering InformationFeatures and Capabilities Leak Rate = Flow Rate x Gas Concentration Functional OverviewFront View Names and Functions of ComponentsRear View Interior Standard Probe with LED and Programmable Pushbutton Standard ProbeSmart Probe Smart Probe Keylock Function System Menu Menu SystemConnecting the AC Power Cord Connecting the ProbePreparing for Operation Turning on the InstrumentMain Menu System Setup Menu System SetupGas Type Leak Units4 4-20 mA Loop RelaysReset Defaults Pchk ModeBrightness ClockRange Configuring the Setups FunctionSetup Name Setpoint Feedback ModeSearch Auto Zero CalibrationExternal Relay Connections Typical Relay 1 Wiring4-40 mA Current Loop Connection MA Current Loop ConnectorPreparing for Operation H25-IR Selecting Internal or External Calibration CalibrationInternal Calibration Selection Calibration Data MenuExternal Calibration Selection and Setup Internal Calibration CALExternal Calibration Material Required ProcedureCAL Factor Improving PPM Measurement Accuracy using the CAL Factor Restoring Factory Calibration Adjusting the CAL FactorCalibration H25-IR Power Using the H25-IRInitial Setup OperationRange Selection Setup SelectionSearching for a Leak Volume AdjustmentMeasuring the PPM Level Measuring the Leak RateLog Menu Logging Measured ReadingsWorking with Logged Measurements Clearing the Log What is PCHK? What to Do when a Fault OccursDiagnostics Menu RS-232 CommunicationOperation H25-IR Sensor Data MaintenanceDiagnostics Menu Last Fault IR Emitter Factory MenuPressure Factory Factory MenuLeak Rate Auto GainLeak Gas Leak TempSensor Cal Leak TempcoFirmware Model SelectProbe Type Items Required Flashing MemorySelect Setup Communications Select File Load Flash Image Removing the Top Cover Part ReplacementProbe Tip Filter & O-Ring Replacement Fuse ReplacementInternal Filter Replacement Replacement Parts Parts and ServiceUnited States Service CentersCFCs, HCFCs, HFCs and Halogens SpecificationsSpecifications H25-IR Continuous Appendix a Factory DefaultsAppendix a H25-IR H25-IR Appendix a Headquarters Hunt Valley Circle, New Kensington, PA