Bacharach H25-IR manual Appendix a Factory Defaults, Continuous

Page 57

H25-IR

Appendix A

 

 

APPENDIX A – Factory Defaults

Table A-1 lists the factory default parameters that are determined by the instrument’s part number (as marked on the rear panel), while Table A-2 lists the default parameters that are user definable.

Table A-1. Default Parameters Defined by Part Number

Part No.

Gas Type

Leak Units

Range

PCHK Mode

Leak Source

3015-4348

R134a*

Oz/yr

Small

Auto

Internal

3015-4434

R600a

g/yr

Small

At CAL

Internal

3015-4448

R134a*

g/yr

Small

At CAL

Internal

3015-4455

R600a

g/yr

Small

At CAL

External

3015-4464

R600a

Oz/yr

Small

Auto

Internal

3015-4465

R600a

Oz/yr

Small

Auto

External

3015-4466

R227

Oz/yr

Small

Auto

Internal

3015-4472

CO2

Oz/yr

Small

Auto

External

3015-4473

CO2

Oz/yr

Small

Auto

Internal

3015-4475

R134a*

g/yr

Small

At CAL

External

3015-4477

SF6

Oz/yr

Small

Auto

Internal

3015-4479

SF6

Oz/yr

Small

Auto

External

3015-4482

CO2

g/yr

Small

At CAL

External

3015-4483

CO2

g/yr

Small

At CAL

Internal

3015-4485

R134a*

Oz/yr

Small

Auto

External

3015-4487

SF6

g/yr

Small

At CAL

Internal

3015-4489

SF6

g/yr

Small

At CAL

External

3015-4496

R227

Oz/yr

Small

Auto

External

3015-4578

R134a*

g/yr

Small

At CAL

Internal

3015-4588

R600a

g/yr

Small

At CAL

Internal

3015-4589

SF6

g/yr

Small

At CAL

Internal

3015-4594

CO2

g/yr

Small

At CAL

Internal

3015-4659

R134a*

g/yr

Small

At CAL

External

3015-4660

R600a

g/yr

Small

At CAL

External

3015-4661

SF6

g/yr

Small

At CAL

External

3015-4662

CO2

g/yr

Small

At CAL

External

*This instrument is capable of detecting CFC, HCFC, HFC and Halogen gases other than R134a. Refer to Section 7 Specifications for a complete list of gases.

Table A-2. Default Parameters Defined by User

Parameter

Default Setting

Relays

NOT USED

Loop

0.016 ppm

Setup Name

SETUP NO. 1

 

SETUP NO. 2

 

SETUP NO. 3

 

SETUP NO. 4

Feedback Mode

CONTINUOUS

Setpoint

00.0000

Log Limit

999.00

All of the above parameters can be reset to their default settings as described in

Section 2.4.9 Reset Defaults.

Instruction 3015-4342

53

Image 57
Contents Infrared Refrigerant Gas Leak Detector H25-IRRegister Your Warranty by Visiting WarrantyTable of Contents Parts and Service Hazard Symbols Safety PrecautionsAC Power and Grounding IntroductionExplosive Atmosphere CleaningWorking Inside the Instrument Misuse and Modifications to Instrument Case of MalfunctionUnpacking and Initial Checks Ordering InformationFeatures and Capabilities Leak Rate = Flow Rate x Gas Concentration Functional OverviewFront View Names and Functions of ComponentsRear View Interior Standard Probe with LED and Programmable Pushbutton Standard ProbeSmart Probe Smart Probe Keylock Function System Menu Menu SystemConnecting the AC Power Cord Connecting the ProbePreparing for Operation Turning on the InstrumentMain Menu System Setup Menu System SetupGas Type Leak Units4 4-20 mA Loop RelaysReset Defaults Pchk ModeBrightness ClockConfiguring the Setups Function Setup NameRange Setpoint Feedback ModeSearch Auto Zero CalibrationExternal Relay Connections Typical Relay 1 Wiring4-40 mA Current Loop Connection MA Current Loop ConnectorPreparing for Operation H25-IR Selecting Internal or External Calibration CalibrationInternal Calibration Selection Calibration Data MenuExternal Calibration Selection and Setup Internal Calibration CALExternal Calibration Procedure CAL FactorMaterial Required Improving PPM Measurement Accuracy using the CAL Factor Restoring Factory Calibration Adjusting the CAL FactorCalibration H25-IR Power Using the H25-IRInitial Setup OperationRange Selection Setup SelectionSearching for a Leak Volume AdjustmentMeasuring the PPM Level Measuring the Leak RateLogging Measured Readings Working with Logged MeasurementsLog Menu Clearing the Log What is PCHK? What to Do when a Fault OccursDiagnostics Menu RS-232 CommunicationOperation H25-IR Maintenance Diagnostics MenuSensor Data Last Fault IR Emitter Factory MenuPressure Factory Factory MenuLeak Rate Auto GainLeak Gas Leak TempSensor Cal Leak TempcoModel Select Probe TypeFirmware Items Required Flashing MemorySelect Setup Communications Select File Load Flash Image Removing the Top Cover Part ReplacementProbe Tip Filter & O-Ring Replacement Fuse ReplacementInternal Filter Replacement Replacement Parts Parts and ServiceUnited States Service CentersCFCs, HCFCs, HFCs and Halogens SpecificationsSpecifications H25-IR Continuous Appendix a Factory DefaultsAppendix a H25-IR H25-IR Appendix a Headquarters Hunt Valley Circle, New Kensington, PA