Installation (for qualified installers only)

Wall Switch or Thermostat Installation

Wiring Diagram (Millivolt System)

Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace. The switch must be installed by a qualified installer.

The included wall switch may be installed following the directions below. An optional thermostat may also be installed. It is attached to the gas control valve in the same manner.

Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

On/Off Switch (on fireplace)

Red Brown

Thermocouple

Thermopile

Piezo Igniter

Copper Co-Axial

Wire

Red

White

Orange

Spark Electrode

Pilot Hood

Optional Wall Switch,

Thermostat, or

Remote Control

Wall Switch Installation

1. Attach the included wire to the gas control valve.

Attach the two wires to the top and bottom posts on the gas control valve (orientation does not matter).

2.Determine a location for the wall switch (the wire is a maximum 25' long). Route the wire through the gas inlet hole (either side) to the junction box and attach following the directions below. Set the on/off switch on the appliance to "OFF" to control the appliance with the wall switch.

Insert the wire

a through the back of the mounted junction box (your junction box may look different). Expose 1/2" of each wire. Secure the wires to the posts on the side of the on/off switch (orientation does not matter).

From

Appliance

Standard

Screwdriver

Carefully pack the wires into the b junction box. Attach the switch

to the junction box. Attach the switchplate to the switch.

Standard

Screwdriver

Travis Industries

4070201

100-01182_002

Image 20
Contents 864 HH Fireplace Overview Listing DetailsTable of Contents Safety Precautions Safety WarningsSafety Precautions Dimensions Installation OptionsHeating Specifications Installation Overview Recommended Installation ProcedurePacking List Additional Items RequiredMassachusetts Requirements Requirements for the Commonwealth of MassachusettsTop Vent or Rear Vent Configuration Converting Fireplace to Top Vent ConfigurationConverting the Fireplace to Top Vent Do not Over Tighten ScrewsRaised Fireplaces Fireplace Placement RequirementsClearances Minimum Framing Dimensions Rear Vent Configuration Minimum 49 Fireplace Enclosure HeightMinimum Framing Dimensions Top Vent Configuration Nailing Brackets Corner Installations Rear Vent Configuration Corner Installations Top Vent Configuration Gas Line Requirements FuelGas Line Connection Gas Inlet PressureGas Line Location Left Side Gas Inlet preferredElectrical Connection required Wall Switch Installation Wall Switch or Thermostat InstallationWiring Diagram Millivolt System Altitude Considerations Vent RequirementsVent Clearances Vent Installation Approved VentRestrictor Position Approved Vent ConfigurationsExhaust Restrictor Adjustment Intake Restrictor Adjustment Diffuser Plate Adjustment Diffuser Side ViewExhaust Restrictor Removal 0feet 5feet 22 max Feet 10feet 15feet Rear Vent Configuration with Vertical Termination Top Vent Configuration with Horizontal Termination Feet 21 max 5feet 10feet 15feetTop Vent Configuration with Vertical Termination May use 8 or 6-5/8 Diameter vent see page for DetailsTermination Requirements Hearth Requirements Floor Mounted FireplacesDrywall Installation Facing RequirementsOptional Faceplates Sizing Chart Facing OverviewFront View Raised Fireplace with no Hearth Front View Thick Facing with Fireplace Xtrordinair FPX Arched Faces Thick Facing Installation Side Floor-Mounted Fireplace with HearthMantel Requirements Side View Installation Example Build-In with Horizontal Termination Horizontal Termination Section FirestopPilot Flame Inspection Steps for Finalizing the InstallationStarting the Pilot Flame Finalizing the Installation for qualified installers only Air Shutter AdjustmentGlass Frame Removal and Installation Based upon the face being used, eitherFinalizing the Installation for qualified installers only Fireback and Grate Installation Right Log Installation Log Set InstallationRear Log Installation Left Log Installation Right Twig Installation Verify Rear LOG PositionEmber Installation Center Twig InstallationFront Twigs Installation LP Conversion Instructions Follow the directions below to replace the orifices Slotted Screwdriver Or T-20 Torx Grill Installation Upper Grill InstallationOption # 2 Remote Thermostat Remote Control Receiver Installation 2 OptionsOption # 1 Remote Thermostat Special Instructions for 864 HH Extra Room Power Heat Duct skuNew Wire Hook-Up Installation Overview Length =Duct Installation Instructions LengthFloor Mounting Attach the grill and wall adapter, if necessary Wiring Diagram -864TRV Operating Instructions OFFAccent Light Installation sku Optional Equipment for qualified installers only Optional Wall-Mounted Rheostat Accent Light OperationOptional Equipment for qualified installers only 68Index Index