North Star 864 HH installation manual Follow the directions below to replace the orifices

Page 53

Finalizing the Installation (for qualified installers only)

53

3Follow the directions below to replace the orifices.

a Slide the air shutters all the way to the left.

Rear Orifice

Front Orifice

Manifold

 

b

c

Use a 1/2” open end wrench to unscrew both orifices.

Apply thread sealant to the LP orifices prior to installation. Use the chart below to identify the correct orifices.

1/2" Wrench

Front Burner

Orifice

Rear Burner

Orifice

Look here for the orifice identification

LP NG

Front 1.2mm #45

Rear #55 #45

Manifold

5/16”

d

Screw the LP orifice in so the orifice shoulder protrudes 5/16” (indicating full insertion).

4Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice

a

Lift the pilot hood

off the pilot

 

 

assembly.

c

Remove the orifice and replace with the LP orifice. Screw the

orifice all the way in and replace the pilot hood.

 

 

Orifice Identification:

b Use a hex wrench to unscrew the orifice.

5/32" Hex

NOTE: when re-attaching, this pin lines up with the notch in the pilot hood.

35

LP (Propane) Orifice

35

NG (Natural Gas) Orifice

62

© Travis Industries

4070201

100-01182_002

Image 53
Contents 864 HH Fireplace Listing Details OverviewTable of Contents Safety Warnings Safety PrecautionsSafety Precautions Dimensions Installation OptionsHeating Specifications Recommended Installation Procedure Installation OverviewPacking List Additional Items RequiredRequirements for the Commonwealth of Massachusetts Massachusetts RequirementsConverting Fireplace to Top Vent Configuration Top Vent or Rear Vent ConfigurationDo not Over Tighten Screws Converting the Fireplace to Top VentRaised Fireplaces Fireplace Placement RequirementsClearances Minimum 49 Fireplace Enclosure Height Minimum Framing Dimensions Rear Vent ConfigurationMinimum Framing Dimensions Top Vent Configuration Nailing Brackets Corner Installations Rear Vent Configuration Corner Installations Top Vent Configuration Fuel Gas Line RequirementsGas Line Connection Gas Inlet PressureLeft Side Gas Inlet preferred Gas Line LocationElectrical Connection required Wall Switch Installation Wall Switch or Thermostat InstallationWiring Diagram Millivolt System Altitude Considerations Vent RequirementsVent Clearances Approved Vent Vent InstallationRestrictor Position Approved Vent ConfigurationsExhaust Restrictor Adjustment Intake Restrictor Adjustment Diffuser Side View Diffuser Plate AdjustmentExhaust Restrictor Removal 0feet 5feet 22 max Feet 10feet 15feet Rear Vent Configuration with Vertical Termination Feet 21 max 5feet 10feet 15feet Top Vent Configuration with Horizontal TerminationMay use 8 or 6-5/8 Diameter vent see page for Details Top Vent Configuration with Vertical TerminationTermination Requirements Floor Mounted Fireplaces Hearth RequirementsFacing Requirements Drywall InstallationFacing Overview Optional Faceplates Sizing ChartFront View Raised Fireplace with no Hearth Front View Thick Facing with Fireplace Xtrordinair FPX Arched Faces Floor-Mounted Fireplace with Hearth Thick Facing Installation SideMantel Requirements Side View Horizontal Termination Section Firestop Installation Example Build-In with Horizontal TerminationPilot Flame Inspection Steps for Finalizing the InstallationStarting the Pilot Flame Air Shutter Adjustment Finalizing the Installation for qualified installers onlyBased upon the face being used, either Glass Frame Removal and InstallationFinalizing the Installation for qualified installers only Fireback and Grate Installation Right Log Installation Log Set InstallationRear Log Installation Left Log Installation Verify Rear LOG Position Right Twig InstallationEmber Installation Center Twig InstallationFront Twigs Installation LP Conversion Instructions Follow the directions below to replace the orifices Slotted Screwdriver Or T-20 Torx Upper Grill Installation Grill InstallationOption # 2 Remote Thermostat Remote Control Receiver Installation 2 OptionsOption # 1 Remote Thermostat Special Instructions for 864 HH Extra Room Power Heat Duct skuNew Wire Hook-Up Length = Installation OverviewLength Duct Installation InstructionsFloor Mounting Attach the grill and wall adapter, if necessary Wiring Diagram -864TRV OFF Operating InstructionsAccent Light Installation sku Optional Equipment for qualified installers only Accent Light Operation Optional Wall-Mounted RheostatOptional Equipment for qualified installers only Index 68Index