North Star 864 HH installation manual Exhaust Restrictor Removal

Page 26

26

Installation (for qualified installers only)

Rear Vent Configuration with Horizontal Termination (no vertical rise)

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and diffuser positions.

HINT: Travis Industries provides a minimum rear vent kit (sku 98900168). It includes a 4” section and a horiztontal termination cap.

Vent with No 45° Elbow

3 feet

0 feet

0feet

(max)

 

4'

Exhaust Restrictor Removed

Intake Restrictor # 1 (stock)

Diffuser Position # 1 (stock)

Min. 4" Horizontal Section

Max.48" Horizontal Section(s)

Vent with 1 45° Elbow

3 feet

0 feet

0feet

(max)

 

2'

See the charts above to determine maximum vent

Optional 45° Elbow

Termination

Exhaust Restrictor Removed

Intake Restrictor # 1 (stock)

Diffuser Position # 1 (stock)

Min. 4" Horizontal Section

Max. 24" Horizontal Section(s)

EXHAUST RESTRICTOR REMOVAL

 

Firebox

 

Roof

Back

 

 

Wall

of

Firebox

 

If venting to the rear with no vertical rise, remove and discard the exhaust restrictor. Replace the screws in the same holes.

Travis Industries

4060907

100-01182

Image 26
Contents 864 HH Fireplace Overview Listing DetailsTable of Contents Safety Precautions Safety WarningsSafety Precautions Dimensions Installation OptionsHeating Specifications Packing List Installation OverviewRecommended Installation Procedure Additional Items RequiredMassachusetts Requirements Requirements for the Commonwealth of MassachusettsTop Vent or Rear Vent Configuration Converting Fireplace to Top Vent ConfigurationConverting the Fireplace to Top Vent Do not Over Tighten ScrewsRaised Fireplaces Fireplace Placement RequirementsClearances Minimum Framing Dimensions Rear Vent Configuration Minimum 49 Fireplace Enclosure HeightMinimum Framing Dimensions Top Vent Configuration Nailing Brackets Corner Installations Rear Vent Configuration Corner Installations Top Vent Configuration Gas Line Connection Gas Line RequirementsFuel Gas Inlet PressureGas Line Location Left Side Gas Inlet preferredElectrical Connection required Wall Switch Installation Wall Switch or Thermostat InstallationWiring Diagram Millivolt System Altitude Considerations Vent RequirementsVent Clearances Vent Installation Approved VentRestrictor Position Approved Vent ConfigurationsExhaust Restrictor Adjustment Intake Restrictor Adjustment Diffuser Plate Adjustment Diffuser Side ViewExhaust Restrictor Removal 0feet 5feet 22 max Feet 10feet 15feet Rear Vent Configuration with Vertical Termination Top Vent Configuration with Horizontal Termination Feet 21 max 5feet 10feet 15feetTop Vent Configuration with Vertical Termination May use 8 or 6-5/8 Diameter vent see page for DetailsTermination Requirements Hearth Requirements Floor Mounted FireplacesDrywall Installation Facing RequirementsOptional Faceplates Sizing Chart Facing OverviewFront View Raised Fireplace with no Hearth Front View Thick Facing with Fireplace Xtrordinair FPX Arched Faces Thick Facing Installation Side Floor-Mounted Fireplace with HearthMantel Requirements Side View Installation Example Build-In with Horizontal Termination Horizontal Termination Section FirestopPilot Flame Inspection Steps for Finalizing the InstallationStarting the Pilot Flame Finalizing the Installation for qualified installers only Air Shutter AdjustmentGlass Frame Removal and Installation Based upon the face being used, eitherFinalizing the Installation for qualified installers only Fireback and Grate Installation Right Log Installation Log Set InstallationRear Log Installation Left Log Installation Right Twig Installation Verify Rear LOG PositionEmber Installation Center Twig InstallationFront Twigs Installation LP Conversion Instructions Follow the directions below to replace the orifices Slotted Screwdriver Or T-20 Torx Grill Installation Upper Grill InstallationOption # 2 Remote Thermostat Remote Control Receiver Installation 2 OptionsOption # 1 Remote Thermostat Special Instructions for 864 HH Extra Room Power Heat Duct skuNew Wire Hook-Up Installation Overview Length =Duct Installation Instructions LengthFloor Mounting Attach the grill and wall adapter, if necessary Wiring Diagram -864TRV Operating Instructions OFFAccent Light Installation sku Optional Equipment for qualified installers only Optional Wall-Mounted Rheostat Accent Light OperationOptional Equipment for qualified installers only 68Index Index