North Star 864 HH installation manual Gas Line Location, Left Side Gas Inlet preferred

Page 18

18

Installation (for qualified installers only)

Gas Line Location

Left Side Gas Inlet (preferred)

A 2" high by 3" wide opening is located behind the gas inlet cover plate (it is 2" above the base of the fireplace).

The Gas Inlet is

3/8" FPT

6-3/4"

You may remove this cover plate to install the gas line. The cover plate has a 7/8" diameter hole (covered with a push plug). By rotating the plate 180° the hole may be re-located. You may also secure the plate in a customized location using the self-drilling screws.

Right Side Gas Inlet

A 12" flex tube and shutoff valve is included with the fireplace. The shutoff valve accepts a 1/2"MPT.

A 2" high by 3" wide opening is located behind the gas inlet cover plate (it is 1-3/8" above the base of the fireplace).

The Gas Inlet is

3/8" FPT

6-1/4"

18"

A 12" flex tube and shutoff valve is included with the fireplace. The shutoff valve accepts a 1/2"MPT.

You may remove this cover plate to install the gas line. The cover plate has a 7/8" diameter hole (covered with a push plug) in line with the gas inlet on the gas control valve. By rotating the plate 180° the hole may be re-located. You may also secure the plate in a customized location using the self- drilling screws.

Travis Industries

4070201

100-01182_002

Image 18
Contents 864 HH Fireplace Overview Listing DetailsTable of Contents Safety Precautions Safety WarningsSafety Precautions Installation Options Heating SpecificationsDimensions Packing List Installation OverviewRecommended Installation Procedure Additional Items RequiredMassachusetts Requirements Requirements for the Commonwealth of MassachusettsTop Vent or Rear Vent Configuration Converting Fireplace to Top Vent ConfigurationConverting the Fireplace to Top Vent Do not Over Tighten ScrewsFireplace Placement Requirements ClearancesRaised Fireplaces Minimum Framing Dimensions Rear Vent Configuration Minimum 49 Fireplace Enclosure HeightMinimum Framing Dimensions Top Vent Configuration Nailing Brackets Corner Installations Rear Vent Configuration Corner Installations Top Vent Configuration Gas Line Connection Gas Line RequirementsFuel Gas Inlet PressureGas Line Location Left Side Gas Inlet preferredElectrical Connection required Wall Switch or Thermostat Installation Wiring Diagram Millivolt SystemWall Switch Installation Vent Requirements Vent ClearancesAltitude Considerations Vent Installation Approved VentApproved Vent Configurations Exhaust Restrictor AdjustmentRestrictor Position Intake Restrictor Adjustment Diffuser Plate Adjustment Diffuser Side ViewExhaust Restrictor Removal 0feet 5feet 22 max Feet 10feet 15feet Rear Vent Configuration with Vertical Termination Top Vent Configuration with Horizontal Termination Feet 21 max 5feet 10feet 15feetTop Vent Configuration with Vertical Termination May use 8 or 6-5/8 Diameter vent see page for DetailsTermination Requirements Hearth Requirements Floor Mounted FireplacesDrywall Installation Facing RequirementsOptional Faceplates Sizing Chart Facing OverviewFront View Raised Fireplace with no Hearth Front View Thick Facing with Fireplace Xtrordinair FPX Arched Faces Thick Facing Installation Side Floor-Mounted Fireplace with HearthMantel Requirements Side View Installation Example Build-In with Horizontal Termination Horizontal Termination Section FirestopSteps for Finalizing the Installation Starting the Pilot FlamePilot Flame Inspection Finalizing the Installation for qualified installers only Air Shutter AdjustmentGlass Frame Removal and Installation Based upon the face being used, eitherFinalizing the Installation for qualified installers only Fireback and Grate Installation Log Set Installation Rear Log InstallationRight Log Installation Left Log Installation Right Twig Installation Verify Rear LOG PositionCenter Twig Installation Front Twigs InstallationEmber Installation LP Conversion Instructions Follow the directions below to replace the orifices Slotted Screwdriver Or T-20 Torx Grill Installation Upper Grill InstallationRemote Control Receiver Installation 2 Options Option # 1 Remote ThermostatOption # 2 Remote Thermostat Extra Room Power Heat Duct sku New Wire Hook-UpSpecial Instructions for 864 HH Installation Overview Length =Duct Installation Instructions LengthFloor Mounting Attach the grill and wall adapter, if necessary Wiring Diagram -864TRV Operating Instructions OFFAccent Light Installation sku Optional Equipment for qualified installers only Optional Wall-Mounted Rheostat Accent Light OperationOptional Equipment for qualified installers only 68Index Index