Domestic Piping |
|
| |
SECTION IV - Domestic Piping |
|
| |
CAUTION |
| ||
|
| ||
General Piping Requirements |
|
| |
The Temperature / Pressure relief valve | |||
• All plumbing must meet or exceed all | is not intended for constant duty, such as | ||
local, state and national plumbing codes. | relief of pressure due to normal thermal | ||
• Use pipe dope or tape suitable for | expansion. | ||
|
| ||
potable water. | Water Hammer | ||
• Use isolation valves to isolate system | |||
|
| ||
components. | Water hammer is the effect of sudden pres- | ||
• Install unions for easy removal of the | sure changes occurring in the domestic pip- | ||
ing. These pressure changes are typically | |||
PERFORMANCE PLUS from the sys- | |||
the result of “fast acting” positive | |||
tem piping. | |||
valves closing. These types of valves can | |||
| |||
Domestic Supply Pressure | be typically found on dishwashers and | ||
clothes washers. | |||
For applications in which the domestic sup- | The effects of water hammering can cause | ||
ply pressure exceeds 70 psig it is recom- | damage to system components and tank | ||
mended to install a pressure reducing valve | welds on the unit. | ||
on the cold water supply. | Installation of hammer arresters is recom- | ||
Maintaining the cold water supply at or | |||
mended at these types of appliances, which | |||
below 70 psig will prevent normal thermal | incorporate | ||
expansion from repeatedly forcing the T&P | valves. Consult the manufacturer of water | ||
relief valve open. | hammer arresters for recommendation on | ||
| sizing and installation requirements. |
Thermal Expansion
If the cold water supply contains a backflow preventer, check valve and / or a pressure reducing valve, the installer must install a domestic thermal expansion tank on the cold water supply. (See Fig. 6 page 17)
Installing a thermal expansion tank will prevent normal thermal expansion from repeatedly forcing the T&P relief valve open.
When installing a thermal expansion tank ensure the charge pressure of the tank is equal to the cold water supply pressure at the point of installation. Consult the ther- mal expansion tank manufacturer’s instruc- tions for further information on installation and sizing.
Temperature / Pressure Relief Valve
The PERFORMANCE PLUS has a factory installed Temperature / Pressure Relief valve. Ensure the rating of the T&P relief valve is correctly sized as follows per AGA:
|
|
|
|
| Model | AGA Rating |
|
| PG | 100,000 Btu/hr |
|
| PG | 200,000 Btu/hr |
|
| PG | 200,000 Btu/hr |
|
| PG | 200,000 Btu/hr |
|
| PG | 200,000 Btu/hr |
|
|
|
|
|
14