ENGLISH
PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS.
NOTE: Before reading these instructions, please unfold the back page for the corresponding illustrations
Descriptions
Fig 1/2
A.Water tank
B.Housing
C.Locking clips
D.Tank handle
E.Misting Chamber
F.Base Tray
G.Control Panel
H.Outlet Grill
I.Humidistat (on supply cord)
Fig 3.
J.Mode/Off Button
K.Humidity Up Button
L.Humidity Down Button
M.Timer Light
N.Reset Light
O.Humidity Display
Fig 4.
B.Housing, F. Base Tray,
P. Heating Element, Q. Boiling chamber
SAFETY PRECAUTIONS
When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
1.Read all instructions before using the appliance.
2.To avoid fire or shock hazard, plug the appliance directly into an electrical outlet and fully insert the plug.
3.Keep the cord out of heavy traffic areas.
To avoid fire hazard, NEVER put the cord under rugs, or near radiator, stoves, or heaters.
4.DO NOT place humidifier near heat sources such as stoves, radiators, and heaters.
Do locate your humidifier on an inside wall near an electrical outlet. The humidifier should be at least 10cm/4" away from the wall for best results.
5.WARNING: This humidifier produces hot steam and therefore should not be placed in an area where it is accessible to children.
Never use a humidifier in a closed room. (i.e.: doors and windows closed) as it may result in
excessive humidity.
6.WARNING: Do not attempt to refill humidifier without first unplugging the unit from it's electrical outlet. Failure to heed this warning may cause personal injury. Be sure to pull by the plug and not the cord.
7.NEVER drop or insert any object into any openings. DO NOT place hands, face, or body directly over or near Moisture Outlet while unit is in operation. DO NOT cover Moisture Outlet or place anything over it while the unit is operating.
8.DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment, or repair.
9.Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause
fire, electric shock, or injury to persons. The use of attachments not recommended or sold by The Holmes Group, may cause hazards.
10.DO NOT use outdoors.
11.Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for use under the humidifier. NEVER place it on a surface that may become damaged by exposure to water and moisture (i.e. finished floor).
12.DO NOT allow the Moisture Outlet to directly face the wall. Moisture could cause damage,
particularly to wallpaper.
13.Humidifier should be unplugged when not in use 14.NEVER tilt, move, or attempt to empty unit
while it is operating. Shut off and unplug before removing the water tank and moving the unit. DO NOT attempt to remove the water tank within 15 minutes after the humidifier is turned off and unplugged. Serious injury may result because of the high temperature of the water.
15.This humidifier requires daily and weekly maintenance to operate appropriately. Refer to daily and weekly cleaning procedures.
16.NEVER use detergents, petrol, glass cleaner, furniture polish, paint thinner, or other household solvents to clean any part of the humidifier.
17.Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier OFF.
18.DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. The inside of the unit contains no user serviceable parts. All servicing should be
2
performed by qualified personnel only. 19.If the supply cord is damaged, it must be
replaced by the manufacturer or its service agent or a similarly qualified person.
20.Should the humidifier stop working, first check the fuse in the plug (UK only) or fuse/circuit breaker at the distribution board is operating, before contacting the manufacturer or service agent.
PLEASE SAVE THESE INSTRUCTIONS Please note that this is an electrical appliance, and requires attention when in use.
HOW YOUR WARM MIST HUMIDIFIER WORKS
Your Bionaire™ Warm Mist Humidifier is designed to allow the proper amount of water to flow out of the tank and into the Heating Chamber where the Electronic Thermal Control Heating Element warms the water. Air is drawn in through the grill openings located in the back of the unit and mixed with steam in the misting chamber. The warm mist is then dispersed out of the top of the misting chamber through the outlet grill and into the room.
NOTE: A humidity level below 20% can be unhealthy and uncomfortable. The recommended humidity level is between 40%-50%.
PRE-OPERATING INSTRUCTIONS (See Figs. 1 - 4)
1.Be sure the Humidifier is switched to OFF and the unit is disconnected from the electrical outlet.
2.Select a location for your Humidifier, on a flat surface, about 10cm (4") away from the wall. DO NOT place the Humidifier on a finished floor on or near furniture which can be damaged by moisture or water. Place on a moisture-resistant surface.
Filling the Water Tank
NOTE: This humidifier holds about 5.6 litres of water in the tank and humidifier base. The humidifier will produce up to 11.5 litres of moisture over a 24-hour period, depending on the room humidity and temperature.
1.If not already removed, remove the Tank from the base of the Humidifier and take it to the cold water tap. Turn the Tank upside down and twist off the Tank Cap by turning counter clockwise. Fill Tank with cool, fresh tap water. DO NOT fill with warm water as this may cause leaking. Replace the Cap on the Tank FIRMLY but do not overtighten.
2.When full, carry Tank to the Humidifier and place onto the Base. The water will
immediately begin to flow into Base.
3.Plug the power cord into a convenient 220/ 240V AC electrical outlet.
OPERATING INSTRUCTIONS (See Figs. 1 - 4)
Your Humidifier is equipped with a technologically advanced AccuSet Plus™ Digital Humidistat. You can set the Humidifier to run continuously in manual mode or set the AccuSet Plus™ Digital Humidistat to your desired humidity setting. The AccuSet Plus™ Digital Humidistat will automatically turn the humidifier ON or OFF, depending on the preset comfort level. The comfort level ranges from 30% to 65% relative humidity.
MANUAL MODE
NOTE: After starting the unit from cold, it will take 5–10 minutes before any noticeable steam is emitted from the Outlet Grill.
1.When plugged in, the Display will show the current room humidity.
2.Press the Button once and the Display will show OFF (OF).
3.To start the unit, push the MODE/OFF Button again for the LOW (LO) manual setting. After 2 seconds, the Display will return to show the current room humidity.
4.Press the Button again for the HIGH (HI) manual setting. After 2 seconds, the Display will return to show the current room humidity.
5.To stop the unit, keep pressing the Button until the Display reads OFF (OF).
AccuSet Plus™ HUMIDISTAT MODE
To take advantage of the AccuSet Plus™ Digital Humidistat -
1.Press the MODE/OFF through Manual LO/HI until the speed is set in either the AUTO LOW (AL) or AUTO HIGH (AH) setting.
2.Adjust the set humidity by using the Up and Down Buttons. The Display will show a setting in the range 30% – 65% and the humidity can be increased/decreased in increments of 5%. When the humidity level is set, the Display will return to show the current room humidity. When the room humidity level rises above the set humidity, the Humidifier will stop. When the humidity level drops below the set humidity, the Humidifier will turn on automatically.
NOTE: The AccuSet™ Humidifier has memory. This means that when you turn the unit back on to AccuSet™ mode, it will remain at the setting the Humidifier was previously set at, unless the unit has been unplugged.
RESET PROCEDURE
NOTE: When the Water Tank is empty and the
3