water in the Heating Chamber is almost empty, the Red RESET light will illuminate and the Automatic Shut Off will activate.
The unit will not operate again until you refill the Water Tank and reset the Humidifier as follows.
1.Unplug the unit.
2.Remove and refill the Water Tank, being sure to follow the Maintenance Instructions. Replace the Tank onto the Base.
3.Wait 5 minutes for the Automatic Shut-Off to reset.
4.After the 5 minutes, plug in the unit and turn the unit on. The RESET light should now be off (if not repeat steps 1 through 4). In about 5 minutes, the Humidifier will begin to produce moisture.
If you do not plan to use the Humidifier for two or more days, make sure any residual water is drained from the Water Tank and Base to prevent algae or bacteria growth.
USING THE PROGRAMMABLE TIMER AccuSet Plus™ allows the user to program the Humidifier to come on at a preset time, or turn off after a set amount of time.
Setting the Off Timer:
1.Select the Mode and temperature you wish the Humidifier to run in.
2.While the Humidifier is running, press and hold the Up and Down Buttons simultaneously for 2 seconds. The display will flash "00".
3.By pressing the Up and Down Buttons, program the Humidifier to turn off up to 16 hours later in increments of 1 hour.
4.After setting the timer, the display will return to show the current room temperature. An indicator on the display will illuminate to show that the timer is activated.
5.After the predetermined length of time has passed, the Humidifier will automatically shut off.
Setting the On Timer:
1.While the Humidifier is off, press and hold the Up and Down Buttons simultaneously for 2 seconds. The display will flash "00".
2.By pressing the Up and Down Buttons, program the Humidifier to turn on up to 16 hours in advance in increments of 1 hour.
3.After the preset length of time has passed, the Humidifier will automatically turn on in Auto Mode HI at 45%.
CLEANING AND MAINTENANCE INSTRUCTION
The following maintenance procedures must be routinely followed in order to ensure proper, efficient operation of your humidifier. The unit WILL FAIL if it is not cleaned properly.
Regular cleaning prevents scale build-up on the heating element and tray. It also prevents micro- organisms from growing on the tray and tank. This ensures that maximum efficiency will be achieved.
We cannot over-emphasize how essential proper cleaning is to the maintenance and continued use of your unit and the avoidance of algae or bacteria build-up.
Regular Maintenance
1.Be sure the unit is OFF and is disconnected from the electrical outlet.
2.Remove the Water Tank then unlock the Housing by moving the two Locks towards the front of the humidifier. Lift the Housing from the Base.
3.Empty water and minerals from the Base and
place in the top rack of the dishwasher.
NOTE: the Base is dishwasher safe
TOP RACK ONLY.
4.Drain the water from the Tank into the sink and rinse tank thoroughly. Leave to dry.
5.Wipe the Heating Element clean with a soft cloth after it has had a chance to cool.
The Electronic Thermal Control Heating element is lined with a Teflon® coating that is designed to provide the easiest cleaning and prolong the operating efficiency of the Humidifier. DO NOT use any metal or hard objects to clean the Heating Element
6.Replace the Housing and lock onto the Base.
7.Follow Operating Instructions.
NOTE: Never use detergents, gasoline, kerosene, glass cleaner, furniture polish, paint thinner or and other household solvent to clean any part of the Humidifier.
De-scaling Maintenance
Scale needs to be removed as it becomes noticeable. We recommend using BionaireTM Clean Away - Humidifier cleaning solution. Apply Solution with a plastic brush to scale surfaces.
Let it soak until residue is softened.
For cleaning the tank, mix 2 capsules of solution with 2 litres of water. Let mixture stand for several minutes, swishing every few minutes. Drain solution and THOROUGHLY RINSE
the tank.
1.Repeat steps 1-3 in the Maintenance section.
2.Clean the tray by partially filling the tray with 200ml of undiluted white vinegar. If the element is heavily scaled, plug the humidifier into an electrical socket and turn it ON for no longer than 15 seconds. After this time turn the humidifier OFF and unplug it from the electrical outlet.
Let solution stand 20 minutes, cleaning all interior surfaces with a soft brush. Dampen a cloth with undiluted white vinegar and wipe out entire tray to remove scale.
3.Rinse with clean warm water to remove scale and the white vinegar solution before beginning to disinfect the tank.
4.Wipe the heating element clean with a soft cloth after it has had a chance to cool.
Disinfect tank:
1.Fill tank with 1 teaspoon of bleach and 3.5 litres of water.
2.Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces.
3.Empty the tank after 20 minutes, and rinse well with water until the bleach smell is gone. Leave to dry
4.Refill the water tank with cool water; replace the water tank. Repeat Operating Instructions.
STORAGE INSTRUCTIONS
If your humidifier will not be in use for two days or more, or at the end of the season follow these instructions.
1.Clean, rinse and thoroughly dry the humidifier as directed in the De-scaling Maintenance section. DO NOT leave any water inside the base or tray.
2.Remove the reservoir cap. Do not store with the reservoir cap in place.
3.Place the humidifier in the original carton and store in a cool, dry place.
4.Clean the humidifier before the next season begins.
SERVICE INSTRUCTIONS
1.Do NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void the warranty. The insides of the unit contain no user serviceable parts. Only qualified personnel should perform all servicing.
2.If you need to exchange the unit, please return it in its original carton, with a sales receipt, to the store where you purchased it.
THIS PRODUCT IS MANUFACTURED TO COMPLY WITH THE E.E.C. DIRECTIVES 73/23/EEC and 89/336/EEC.
FOR U.K. AND IRELAND ONLY:
If the plug is not suitable for the socket outlets in your home, it can be removed and replaced by a plug of the correct type. Please refer to "Installation of a plug" below.
Installation of a plug Applicable to U.K. and Ireland
WARNING - THIS APPLIANCE MUST BE EARTHED
The wires in the mains lead are coloured as
such: | | |
GREEN AND YELLOW - | EARTH |
BROWN | - | LIVE |
BLUE | - | NEUTRAL |
Please note that the colour of these mains wires may not correspond with the colour markings that identify the terminals in your plug. Please proceed as follows:
The wire which is coloured GREEN AND YELLOW must be connected to the terminal which is marked with the letter 'E' or by the earth
symbol or coloured GREEN or GREEN AND YELLOW.
The BROWN coloured wire must be connected to the terminal, which is marked with the letter "L" or is coloured RED.
The BLUE coloured wire must be connected to the terminal, which is marked with the letter "N" or is coloured BLACK.
3 amp
NOTE: If the terminals in the plug are not marked or if you are unsure or in doubt about the installation of the plug please contact a qualified electrician.
If a 13A 3-pin plug is fitted, it must be an ASTA approved plug, conforming to BS1363 standard. Replacement 3A fuses must be BSI or ASTA BS1362 approved.