FLUEING WITH TWO (2) 90° ELBOWS

 

V

H

 

H + H1

 

1´ MIN. (0.30M)

1´ MAX. (0.30M)

2´ MAX. (0.61M)

 

2´ MIN. (0.61M)

2´ MAX. (0.61M)

4´ MAX. (1.22M)

 

3´ MIN. (0.91M)

3´ MAX. (0.91M)

8´ MAX. (2.44M)

 

4´ MIN. (1.22M)

4´ MAX. (1.22M)

10´ MAX. (3.05M)

 

 

H = 8´ MAX.(2.44M)

H+H1= 10´MAX. (3.05M)

 

V + H + H1 = 30’ (9.14M) MAX.

 

 

 

H1

 

 

 

 

 

 

V

 

USE DVP-SERIES

 

H

 

COMPONENTS ONLY.

 

 

V (FT)

 

H + H1

(FT)

 

1' MIN. (0.30 M)

3' MAX. (0.91M)

 

2' MIN. (0.61 M)

5' MAX. (1.52M)

 

3' MIN. (0.91 M)

8' MAX. (2.44M)

V

4' MIN. (1.22 M)

12' MAX. (3.66M)

 

 

H + H1= 12' MAX. (3.66M)

 

V + H + H1= 33' (10.06m) MAX.

 

 

H1

 

 

H

Figure 14.

 

 

 

 

14

Heat & Glo • SL-550TRSI-AUE2079-902 Rev. B • 7/06

Image 14
Contents Model SL-550TRSI-AUE Kensington Boulevard, Lakeville, MN 55044 USAHeat & Glo Quality Systems registered by SGS ICS Table of Contents Diagram of SL-550TRSI-AUE Rear Flue Installation InstructionsTop Flue Framing Dimensions IntroductionSpace heaters Identifying Flue Components Flue System ApprovalsModel Flue Termination Approvals DVP90ST Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 USE SL D-SERIES Vertical FlueingMaximum 10.97M USE DVP-SERIES Components onlyUSE SL D-SERIES Components Only Flueing with ONE 1 90 Elbow USE DVP-SERIES ComponentsFT. V M FT. HM Flueing with TWO 2 90 Elbows+ H FT. M Flueing with TWO 2 90 Elbows Flueing with Three 3 90 Elbows + H1 FT. MFlueing with Three 3 90 Elbows Installing Flue Components Nent and the Outer Heater Wrap Assembling Flue ComponentsInstall Support Brackets Continue Adding Flue ComponentsInstalling Support Brackets Hole and New Framing MembersFlue Termination Connecting the GAS Supply Gas Supply LineIgnition System Wiring Shock RiskBlower FAN Finishing CeilingPilot Assembly Installer TestingInstalling the Trim 3 4 5 6 7 Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Operating Trol Wiring System of this UnitOperating Instructions This Appliance MAY Exhibit a Slight Carbon DepositionSafety & Lighting Information Do not Connect 220/240 VAC to the Control ValveFAN Operation Servicing and MaintenanceGlass Door When IT is HOT Adjustments and Replacement Parts Removal of Components for ServiceParts Replacement Removal of Covers for ServicingMaintenance Tasks Doors Inspect Maintenance TasksTroubleshooting Electronic Ignition SystemPan beneath the burne Log set assembly SL-550TRSI-AUESL-550TRSI-AUE Service Parts List Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Melbourne