Hearth and Home Technologies SL-550TRSI-AUE manual Pan beneath the burne

Page 36

Electronic Ignition System - (continued)

Symptom

Possible Causes

Corrective Actions

10. Glass soots.

a. Flame impingement on

Adjust the log set so that the flame does not impinge on it.

 

logs.

 

 

b. Improper venturi setting. Adjust the air shutter at the base of the burner.

 

c. Debris around venturi.

Inspect the opening at the base of the burner. It is imperative that NO

 

 

material be placed in this opening.

11. Flame burns blue

a. Insufficient oxygen

1. Check to make sure flue cap is installed properly and free of debris.

and lifts off burner.

being supplied.

Make sure that flue system points are tight and have no leaks.

 

 

2. Check to make sure that no material has been placed in the opening at

 

 

the burner base or in the area of the air holes in the center of the base

 

 

pan beneath the burne.

 

 

3. Be sure glass is tighened properly on unit, particularly on top corners.

36

Heat & Glo • SL-550TRSI-AUE2079-902 Rev. B • 7/06

Image 36
Contents Model SL-550TRSI-AUE Kensington Boulevard, Lakeville, MN 55044 USAHeat & Glo Quality Systems registered by SGS ICS Table of Contents Diagram of SL-550TRSI-AUE Installation Instructions Top FlueRear Flue Framing Dimensions IntroductionSpace heaters Flue System Approvals Model Flue Termination ApprovalsIdentifying Flue Components DVP90ST Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Vertical Flueing Maximum 10.97MUSE SL D-SERIES USE DVP-SERIES Components onlyUSE SL D-SERIES Components Only Flueing with ONE 1 90 Elbow USE DVP-SERIES ComponentsFlueing with TWO 2 90 Elbows + H FT. MFT. V M FT. HM Flueing with TWO 2 90 Elbows Flueing with Three 3 90 Elbows + H1 FT. MFlueing with Three 3 90 Elbows Installing Flue Components Nent and the Outer Heater Wrap Assembling Flue ComponentsInstall Support Brackets Continue Adding Flue ComponentsInstalling Support Brackets Hole and New Framing MembersFlue Termination Connecting the GAS Supply Gas Supply LineIgnition System Wiring Shock RiskBlower FAN Finishing CeilingInstaller Testing Installing the TrimPilot Assembly 3 4 5 6 7 Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Trol Wiring System of this Unit Operating InstructionsOperating This Appliance MAY Exhibit a Slight Carbon DepositionSafety & Lighting Information Do not Connect 220/240 VAC to the Control ValveServicing and Maintenance Glass Door When IT is HOTFAN Operation Removal of Components for Service Parts ReplacementAdjustments and Replacement Parts Removal of Covers for ServicingMaintenance Tasks Doors Inspect Maintenance TasksTroubleshooting Electronic Ignition SystemPan beneath the burne Log set assembly SL-550TRSI-AUESL-550TRSI-AUE Service Parts List Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Melbourne