Hearth and Home Technologies manual SL-550TRSI-AUE Service Parts List

Page 38

SL-550TRSI-AUE Service Parts List

IMPORTANT: When ordering, supply serial and model numbers to ensure correct service parts.

ITEM

PARTS

PART NUMBER

1

Valve NG

2098-130

Valve LP

2098-131

 

2

Orifice NG

582-840

Orifice LP

582-057

 

3

Flexible Gas Connector

530-302A

4

Burner Assembly NG

2079-010

Burner Assembly LP

2079-012

 

5

Ignition Cable

2098-147

6

Hood

SRV550-175

7

Glass Door Assembly

GLA-550TRS

8

Dress Guard

2079-040

9

Top Louver

550-251A

10

Lower Door

2079-041

11

Grate

2021-007

12

Base Refractory

550-117

13

Blower Assembly 240V

100-505A

14

Junction Box

2078-025

15

Power Cord

546-251A

16

Pilot Assembly NG

2098-050

Pilot Assembly LP

2098-051

 

17

Switch Assembly

2098-145

18

Interior Top Heat Shield

2079-109

19

Gas Shutoff Assembly

2078-022

20

Rheostat

491-510A

21

Switch Sensor

046-530

22

Log Set Assembly

LOGS-550TRSAUD

23

Log #1

SRV550-715

24

Log #2

SRV347-703

25

Log #3

SRV349-704

26

Log #4

SRV278-705

27

Log #5

SRV540-704

28

Log #6

SRV550-718

29

Log #7

SRV484-703

30

Log #8

SRV347-701

31

Valve Plate Gasket

530-431

32

Pilot Bracket

2079-104

33

Valve Bracket

2089-120

34

Control Cable

2098-143

35

Module, Maxitrol

2098-142

36

240V Adaptor

2098-144

37

Burner Neck Gasket

2045-407

38

Rheostat Knob

100-512

39

Thermocouple Block

2098-146

40

Block Control Wire

2098-148

 

Glass Latch Assembly

386-122A

 

Mineral Wool

050-721

 

Mesh Assembly

561-330A

 

Exhaust Resistor

347-299

 

Accesssories

 

 

Wall Switch Kit, Off White

WSK-21

 

Wall Switch Kit, White

WSK-21W

 

Conversion Kit NG

NGK-550I-AUE

 

Conversion Kit LP

LPK-550I-AUE

38

Heat & Glo • SL-550TRSI-AUE2079-902 Rev. B • 7/06

Image 38
Contents Model SL-550TRSI-AUE Kensington Boulevard, Lakeville, MN 55044 USAHeat & Glo Quality Systems registered by SGS ICS Table of Contents Diagram of SL-550TRSI-AUE Rear Flue Installation InstructionsTop Flue Framing Dimensions IntroductionSpace heaters Identifying Flue Components Flue System ApprovalsModel Flue Termination Approvals DVP90ST Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 USE SL D-SERIES Vertical FlueingMaximum 10.97M USE DVP-SERIES Components onlyUSE SL D-SERIES Components Only Flueing with ONE 1 90 Elbow USE DVP-SERIES ComponentsFT. V M FT. HM Flueing with TWO 2 90 Elbows+ H FT. M Flueing with TWO 2 90 Elbows Flueing with Three 3 90 Elbows + H1 FT. MFlueing with Three 3 90 Elbows Installing Flue Components Nent and the Outer Heater Wrap Assembling Flue ComponentsInstall Support Brackets Continue Adding Flue ComponentsInstalling Support Brackets Hole and New Framing MembersFlue Termination Connecting the GAS Supply Gas Supply LineIgnition System Wiring Shock RiskBlower FAN Finishing CeilingPilot Assembly Installer TestingInstalling the Trim 3 4 5 6 7 Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Operating Trol Wiring System of this UnitOperating Instructions This Appliance MAY Exhibit a Slight Carbon DepositionSafety & Lighting Information Do not Connect 220/240 VAC to the Control ValveFAN Operation Servicing and MaintenanceGlass Door When IT is HOT Adjustments and Replacement Parts Removal of Components for ServiceParts Replacement Removal of Covers for ServicingMaintenance Tasks Doors Inspect Maintenance TasksTroubleshooting Electronic Ignition SystemPan beneath the burne Log set assembly SL-550TRSI-AUESL-550TRSI-AUE Service Parts List Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Melbourne