Hearth and Home Technologies SL-550TRSI-AUE manual FAN Operation, Servicing and Maintenance

Page 32

2.2FAN OPERATION

The accessory fan is wired in series with a speed con- trol switch and a temperature sensor switch. Set the speed control to an "ON" position and light the heater. The temperature sensor switch will automatically start the fan when the switch warms up—and stop the fan when it cools down. You can manually stop the fan by turning the speed control switch to "OFF". See Figure 31 for fan wiring diagram.

3.0SERVICING AND MAINTENANCE

A. HEATER SERVICING: Frequency of heater servic- ing will depend upon use and type of installation.

B.IMPORTANT: TURN OFF GAS AND ELECTRICAL POWER BEFORE SERVICING APPLIANCE. IT IS RECOMMENDED THAT A COMPETENT SERVICE TECHNICIAN PERFORM SERVICE CHECK-UPSAT THE BEGINNING OF EACH HEATING SEASON.

C.The appliance and flue system should be inspected before initial use and at least annually by a qualified field service person.

D.Inspect the external flue cap on a regular basis to make sure that no debris is interfering with the air flow.

E.Keep the control compartment, logs, and burner area surround the logs clean by vacuuming or brushing at least twice a year.

CAUTION: THE LOGS GET VERY HOT - HANDLE ONLY WHEN COOL.

! WARNING: DO NOT USE ABRASIVE CLEANERS ON THE GLASS DOOR AS- SEMBLY. DO NOT ATTEMPT TO CLEAN THE

GLASS DOOR WHEN IT IS HOT.

F.The glass door should be cleaned using a house- hold glass cleaner. DO NOT handle or attempt to clean the glass when it is HOT.

G.Visually inspect the flexible power supply cord; if damaged, contact the service agent for a special replacement cord assembly.

H.In order to properly clean the burner and pilot as- sembly, turn off the gas to the unit and remove the logs exposing the burner and pilot assembly. Clean all foreign materials from top of burner. Check to make sure that the burner orifice is clean.

Visually inspect the pilot periodically. Brush or blow away any dust or linen accumulations. If the pilot ori- fice is plugged, disassembly may be required to re- move any foreign materials from the orifice or tubing.

When the appliance is put back in service check burner flame patterns with Figure 37.

To obtain proper operation, it is imperative that the pi- lot and main burner flame characteristics are steady, not lifting or floating. Typically, the top 3/8-inch (10m) of the thermocouple should be engulfed in the pilot flame (Figure 38).

MAKE SURE THE FLAMES

ARE STEADY—NOT

LIFTING OR FLOATING.

Figure 37.

Pilot Assembly

Figure 38.

32

Heat & Glo • SL-550TRSI-AUE2079-902 Rev. B • 7/06

Image 32
Contents Model SL-550TRSI-AUE Kensington Boulevard, Lakeville, MN 55044 USAHeat & Glo Quality Systems registered by SGS ICS Table of Contents Diagram of SL-550TRSI-AUE Rear Flue Installation InstructionsTop Flue Framing Dimensions IntroductionSpace heaters Identifying Flue Components Flue System ApprovalsModel Flue Termination Approvals DVP90ST Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Vertical Flueing Maximum 10.97MUSE SL D-SERIES USE DVP-SERIES Components onlyUSE SL D-SERIES Components Only Flueing with ONE 1 90 Elbow USE DVP-SERIES ComponentsFT. V M FT. HM Flueing with TWO 2 90 Elbows+ H FT. M Flueing with TWO 2 90 Elbows Flueing with Three 3 90 Elbows + H1 FT. MFlueing with Three 3 90 Elbows Installing Flue Components Nent and the Outer Heater Wrap Assembling Flue ComponentsInstall Support Brackets Continue Adding Flue ComponentsInstalling Support Brackets Hole and New Framing MembersFlue Termination Connecting the GAS Supply Gas Supply LineIgnition System Wiring Shock RiskBlower FAN Finishing CeilingPilot Assembly Installer TestingInstalling the Trim 3 4 5 6 7 Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Trol Wiring System of this Unit Operating InstructionsOperating This Appliance MAY Exhibit a Slight Carbon DepositionSafety & Lighting Information Do not Connect 220/240 VAC to the Control ValveFAN Operation Servicing and MaintenanceGlass Door When IT is HOT Removal of Components for Service Parts ReplacementAdjustments and Replacement Parts Removal of Covers for ServicingMaintenance Tasks Doors Inspect Maintenance TasksTroubleshooting Electronic Ignition SystemPan beneath the burne Log set assembly SL-550TRSI-AUESL-550TRSI-AUE Service Parts List Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Melbourne