Hearth and Home Technologies SL-550TRSI-AUE manual Ignition System Wiring, Shock Risk

Page 23

FLAME SPARKER/

SENSOR

VALVE

 

REMOTE

 

CONTROL

 

ANT.

 

ON/OFF

PILOT

WALL SWITCH

 

IGNITION

IGNITION MODULE

MODULE

6VDC

(6V)

 

 

GROUND

NEUTRAL

HOT

BATTERY PORT

 

 

PLUG IN

ON/OFF

THERMOCOUPLE

BLOCK

SWITCH

(CONNECTED TO

 

BACK OF VALVE)

 

VALVE

GAS LINE

 

CONNECTED TO

 

BACK OF VALVE

 

Figure 30.

 

1.4 IGNITION SYSTEM WIRING

This gas fireplace is equipped with an electronic igni- tion system which operates on a 6 volt system.

This appliance requires 240 VAC to be wired to the factory installed junction box. Check factory installed power cord for damage before using .

CAUTION

Label all wires prior to disconnection when servic- ing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING

Shock Risk

• Replace damaged wire with type 105O C rated wire.

• Wire must have high temperature insulation.

Heat & Glo • SL-550TRSI-AUE2079-902 Rev. B • 7/06

23

Image 23
Contents Kensington Boulevard, Lakeville, MN 55044 USA Model SL-550TRSI-AUEHeat & Glo Quality Systems registered by SGS ICS Table of Contents Diagram of SL-550TRSI-AUE Rear Flue Installation InstructionsTop Flue Introduction Framing DimensionsSpace heaters Identifying Flue Components Flue System ApprovalsModel Flue Termination Approvals DVP90ST Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 USE DVP-SERIES Components only Vertical FlueingMaximum 10.97M USE SL D-SERIESUSE DVP-SERIES Components USE SL D-SERIES Components Only Flueing with ONE 1 90 ElbowFT. V M FT. HM Flueing with TWO 2 90 Elbows+ H FT. M Flueing with TWO 2 90 Elbows + H1 FT. M Flueing with Three 3 90 ElbowsFlueing with Three 3 90 Elbows Installing Flue Components Assembling Flue Components Nent and the Outer Heater WrapContinue Adding Flue Components Install Support BracketsHole and New Framing Members Installing Support BracketsFlue Termination Gas Supply Line Connecting the GAS SupplyShock Risk Ignition System WiringBlower FAN Ceiling FinishingPilot Assembly Installer TestingInstalling the Trim 3 4 5 6 7 Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 This Appliance MAY Exhibit a Slight Carbon Deposition Trol Wiring System of this UnitOperating Instructions OperatingDo not Connect 220/240 VAC to the Control Valve Safety & Lighting InformationFAN Operation Servicing and MaintenanceGlass Door When IT is HOT Removal of Covers for Servicing Removal of Components for ServiceParts Replacement Adjustments and Replacement PartsDoors Inspect Maintenance Tasks Maintenance TasksElectronic Ignition System TroubleshootingPan beneath the burne SL-550TRSI-AUE Log set assemblySL-550TRSI-AUE Service Parts List Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Melbourne