2.0 OPERATING INSTRUCTIONS
This appliance is a balanced flue heater and is designed to operate with all combustion air being siphoned from the outside of the building and all exhaust gases ex- pelled to the outside of the building.
!WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
The control system for this model includes a pilot, elec- tronic module, spark ignitor and thermocouple. It con- sists of a 6V gas control valve/variable regulator and an remote control. The controls are located in the lower compartment behind the lower door, and access is gained by lifting the door up. See Figure 1.
WARNING: DO NOT CONNECT 240 VAC ! TO THE GAS CONTROL VALVE OR CON-
TROL WIRING SYSTEM OF THIS UNIT.
When lit for the first time, the appliance will emit a slight odor for an hour or two, due to paint and lubricants used in the manufacturing process. For the first few minutes after each lighting, vapor may condense and fog the glass and the flames may be blue. After a few minutes this moisture will disappear and within
The heater may produce a noise, caused from metal expansion and contraction as it heats up and cools down. This noise is similar to one that a furnace or heat duct may produce and does not affect the operation or lon- gevity of the heater.
•THE DRESS GUARD IS FITTED TO THIS APPLI- ANCE TO REDUCE THE RISK OF FIRE OR INJURY FROM BURNS AND NO PART OF IT SHOULD BE PERMANENTLY REMOVED. FOR PROTECTION OF YOUNG CHILDREN OR THE INFIRM, A SEC- ONDARY GUARD IS REQUIRED.
•THE GLASS DOOR ASSEMBLY MUST BE IN PLACE AND SEALED AND THE FIXED MESH DRESS GUARD MUST BE IN PLACE ON THE FIREPLACE BEFORE THE UNIT CAN BE PLACED INTO SAFE OPERATION.
•DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE UNIT AND TO REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDERWATER.
•DO NOT OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED, CRACKED, OR BRO- KEN. REPLACEMENT OF THE GLASS DOOR SHOULD BE DONE BY A LICENSED OR QUALI- FIED PERSON. DO NOT STRIKE OR SLAM THE GLASS DOOR.
•THE GLASS DOOR ASSEMBLY SHALL ONLY BE REPLACED AS A COMPLETE UNIT AS SUPPLIED BY THE GAS FIREPLACE MANUFACTURER. NO SUBSTITUTE MATERIALS MAY BE USED.
OPERATING
CAUTIONS
•THIS APPLIANCE MAY EXHIBIT A SLIGHT CARBON DEPOSITION.
•DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.
•DO NOT USE OR STORE FLAM- MABLE MATERI- ALS NEAR THIS APPLIANCE.
•DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
30
FLAME SPARKER/ | |
SENSOR | VALVE |
| REMOTE |
| CONTROL |
| ANT. |
| ON/OFF |
PILOT | WALL SWITCH |
| IGNITION |
IGNITION MODULE | MODULE |
6VDC | (6V) |
| |
| GROUND |
NEUTRAL | HOT |
BATTERY PORT |
|
| PLUG IN |
ON/OFF | THERMOCOUPLE |
BLOCK | |
SWITCH | (CONNECTED TO |
| BACK OF VALVE) |
| VALVE |
GAS LINE |
|
CONNECTED TO |
|
BACK OF VALVE |
|
Figure 36. |
|
Heat & Glo • |