3.5MAINTENANCE TASKS

Doors Inspect

 

Maintenance Tasks

 

1. Inspect for scratches, dents or other damage and repair as necessary.

 

2.

Verify no obstructions to airflow .

 

3.

Verify maintenance of proper clearance to combustible household objects.

Gasket Seal, Glass

1. Inspect gasket seal and its condition.

Assembly and Glass

2.

Inspect glass panels for scratches and nicks that can lead to breakage when exposed to

 

 

heat.

 

3. Confirm there is no damage to glass or glass frame. Replace as necessary.

 

4.

Verify that latches engage properly, clip studs are not stripped, and glass attachment

 

components are intact and operating properly. Replace as necessary.

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot

 

be removed.

Valve Compartment

1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these

and Firebox Top

areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.

 

2.

Remove any foreign objects.

 

3.

Verify unobstructed air circulation.

Logs

1.

Inspect for broken, damaged, or missing logs. Replace as necessary.

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as

 

necessary.

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as

 

necessary.

 

2.

Replace gas fireplace if firebox has been perforated.

Burner Ignition and

1.

Verify burner is properly secured and aligned with pilot or igniter.

Operation

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if

 

 

necessary.

 

3.

Replace ember materials with new dime-size and shape pieces. Do not block ports or

 

obstruct lighting paths.

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

5.

Inspect for lifting or other flame problems.

 

6.

Inspect orifice for soot, dirt or corrosion.

 

7.

Verify manifold and inlet pressures. Adjust regulator as required.

 

8.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

9.

Inspect thermocouple for soot, corrosion and deterioration. Clean with emery cloth or

 

replace as required.

Flueing

1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks,

 

fences or sheds) has been maintained.

 

4.

Inspect for corrosion or separation.

Remote controls

5.

Verify weather stripping, sealing and flashing remains intact.

1.

Verify operation of remote.

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

34

Heat & Glo • SL-550TRSI-AUE2079-902 Rev. B • 7/06

Image 34
Contents Model SL-550TRSI-AUE Kensington Boulevard, Lakeville, MN 55044 USAHeat & Glo Quality Systems registered by SGS ICS Table of Contents Diagram of SL-550TRSI-AUE Top Flue Installation InstructionsRear Flue Framing Dimensions IntroductionSpace heaters Model Flue Termination Approvals Flue System ApprovalsIdentifying Flue Components DVP90ST Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 USE SL D-SERIES Vertical FlueingMaximum 10.97M USE DVP-SERIES Components onlyUSE SL D-SERIES Components Only Flueing with ONE 1 90 Elbow USE DVP-SERIES Components+ H FT. M Flueing with TWO 2 90 ElbowsFT. V M FT. HM Flueing with TWO 2 90 Elbows Flueing with Three 3 90 Elbows + H1 FT. MFlueing with Three 3 90 Elbows Installing Flue Components Nent and the Outer Heater Wrap Assembling Flue ComponentsInstall Support Brackets Continue Adding Flue ComponentsInstalling Support Brackets Hole and New Framing MembersFlue Termination Connecting the GAS Supply Gas Supply LineIgnition System Wiring Shock RiskBlower FAN Finishing CeilingInstalling the Trim Installer TestingPilot Assembly 3 4 5 6 7 Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Operating Trol Wiring System of this UnitOperating Instructions This Appliance MAY Exhibit a Slight Carbon DepositionSafety & Lighting Information Do not Connect 220/240 VAC to the Control ValveGlass Door When IT is HOT Servicing and MaintenanceFAN Operation Adjustments and Replacement Parts Removal of Components for ServiceParts Replacement Removal of Covers for ServicingMaintenance Tasks Doors Inspect Maintenance TasksTroubleshooting Electronic Ignition SystemPan beneath the burne Log set assembly SL-550TRSI-AUESL-550TRSI-AUE Service Parts List Heat & Glo SL-550TRSI-AUE 2079-902 Rev. B 7/06 Melbourne