Hearth and Home Technologies CD4842MR Install Trim, Install Clean Face Components, Install Hood

Page 56

L. Install Trim

Install optional trim/surround kits using the instructions included with the accessory.

Use non-combustible materials to cover the gap between the sheet rock and the appliance (if desired).

Do not obstruct or modify the air inlet/outlet latch covers.

Allow space to lower and remove bottom latch cover.

M. Install Clean Face Components

Carefully remove components from skin pack. See Figure 14.6 for identification of components.

Bottom Latch Cover

(Lower Floor Cover underneath)

Top Latch Cover

Hood

Firescreen

Firescreen Rod

Figure 14.6 Clean Face Components/Skin Pack

Install Hood

Bend screen rod tabs down at a 90-deg. angle. See Figure 14.7.

Figure 14.7 Screen Rod Tab

Install above the glass panel.

Hood must be attached or a fire hazard may result.

Locate the four screws (for 4236) or five screws (for 4842) just inside the upper section of the appliance.

Loosen the screws, but do NOT remove.

Position hood and slide notches over screw heads, ensuring hood also slips into the clips.

See Figure 14.8.

Tighten the screws to hold hood firmly in place.

Figure 14.8 Installing the Hood

Install Top Latch Cover

Insert top latch cover over existing shoulder screws. See Figure 14.9.

Push down until the tabs lock in place.

Figure 14.9 Installing Top Latch Cover

Install Floor Cover

Install floor cover. See Figure 14.10. Floor cover must be installed with brake flange UP and going towards components with notched end to the left of the unit. Do not place cover on top of any components. Move components back if necessary.

When using the RCTS-MLT-HTL Remote for SIT Valve, the hand tab bend must be bent down for clearance of the solenoid.

56

Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev J • 06/08

Image 56
Contents Installation and Operation Models CD4236MR CD4842MRDirect Vent Gas Appliance What to do if you smell gasCongratulations Homeowner Reference InformationUser Guide Table of ContentsInstaller Guide Reference Materials Appliance SetupTroubleshooting Gas Appliance Fireplace Limited Lifetime Warranty Limited Lifetime WarrantyListing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceFor Your Safety Read Before Lighting Lighting Instructions IPIPilot LightingStanding Frequently Asked Questions After Fireplace is LitMaintenance and Service Maintenance Tasks-HomeownerRemote Control Doors, Surrounds, FrontsMaintenance Tasks-Qualified Service Technician Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Model # Framing and ClearancesSelect Appliance Location Construct the Appliance Chase ClearancesMantel Legs or Wall Projections Mantel and Wall ProjectionsMantels Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsOne Elbow Vent DiagramsTop Vent Horizontal Termination Two 45 Elbows replacing One 90 Elbow Two ElbowsInstalled Vertically Three ElbowsTop Vent Vertical Termination No Elbow12 ft 3.66 m min 60 ft 18.29 m max Rear Vent Horizontal Termination One 45 ElbowTwo Elbows Rear Vent Vertical Termination Min Ft 1.83 m max 12 ft 3.66 m min 60 ft 18.29 m max Install Vertical Termination Baffle 17 Flat BaffleVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Installing Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Appliance Preparation Convert from Top Vent to Rear VentOuter Collar, Remove Four Screws 11 Place Outer Collar on Rear of Appliance 16 Cover Plate-Replace Secure and Level the Appliance 20 Proper Positioning, Leveling And Securing Of AnInstall Vent Pipe Attach Pipe to the Firebox AssemblyAssemble Pipe Sections DVP Only Assemble Pipe SectionsAssemble Vent Sections SLP Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall RF4-8 SLP-FSHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components SLP only Install Horizontal Termination Cap InteriorGas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Standing Pilot Ignition System WiringIntellifire Ignition System Wiring Optional Accessories RequirementsElectrical Service and Repair WSK-MLT-HTLJunction Box Installation Wall Switch Installation for Fan Optional Combustible Finishing Facing Material Appliance Setup Replacing Fixed Glass Assembly Install the Log AssemblyRemoving Fixed Glass Assembly Install Trim Install Clean Face ComponentsInstall Hood Install Top Latch CoverInstall Firescreen Assembly Air Shutter SettingInstall Bottom Latch Cover Troubleshooting Standing Pilot Ignition SystemSymptom Possible Cause Corrective Action Intellifire Ignition System Will not ignite. If the pilot Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP Vent ComponentsBEK DVP-BEK2 DVP-TVHW DVP-TRAP DVP-HRC-SS Effective SL-2DVP AdapterParts Service#22 Log/Grate Assembly CD4842M Series Parts Service CD4842M SeriesOptional Components Model # Description Contact Information