B. Intellifire Ignition System

Symptom

Possible Cause

Corrective Action

1. Pilot won’t light. The

A. Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are

ignitor/module makes

 

connected to correct terminals on module and pilot assembly.

noise, but no spark.

 

 

 

B. Loose connections or electrical

Verify no loose connections or electrical shorts in wiring from

 

shorts in the wiring.

module to pilot assembly. Verify connections underneath pilot

 

 

assembly are tight; also verify connections are not grounding out to

 

 

metal chassis, pilot burner, pilot enclosure, mesh screen if present,

 

 

or any other metal object.

 

 

 

 

C. Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be

 

 

approximately .17 inch or 1/8 in. (3 mm).

 

D. Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place a grounded wire about 3/16 in. (5

 

 

mm) away from “I” terminal on module. Place ON/OFF rocker switch

 

 

or wall switch in ON position. If there is no spark at “I” terminal

 

 

module must be replaced. If there is a spark at “I” terminal, module

 

 

is fine. Inspect pilot assembly for shorted sparker wire or cracked

 

 

insulator around electrode. Replace pilot if necessary.

 

 

 

2. Pilot won’t light, there is no

A. No power or transformer

Verify that transformer is installed and plugged into module. Check

noise or spark.

installed incorrectly.

voltage of transformer under load at spade connection on module

 

 

with ON/OFF switch in ON position. Acceptable readings of a good

 

 

transformer are between 3.2 and 2.8 volts AC.

 

 

 

 

B. A shorted or loose connection

Remove and reinstall the wiring harness that plugs into module.

 

in wiring configuration or wiring

Verify there is a tight fit. Verify pilot assembly wiring to module.

 

harness.

Remove and verify continuity of each wire in wiring harness.

 

 

Replace any damaged components.

 

 

 

 

C. Improper wall switch wiring.

Verify that 110/VAC power is “ON” to junction box.

 

 

 

 

D. Module not grounded.

Verify black ground wire from module wire harness is grounded to

 

 

metal chassis of appliance.

 

E. Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place ON/OFF rocker switch or wall

 

 

switch in ON position. If there is no spark at “I” terminal module

 

 

must be replaced. If there is a spark at “I” terminal, module is fine.

 

 

Inspect pilot assembly for shorted sparker wire or cracked insulator

 

 

around electrode.

 

 

 

3. Pilot sparks, but Pilot will

A. Gas supply.

Verify that incoming gas line ball valve is “open”. Verify that inlet

not light.

 

pressure reading is within acceptable limits, inlet pressure must not

 

 

exceed 14 in. W.C.

 

B. Ignitor gap is incorrect.

Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in (3

 

 

mm).

 

C. Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

 

 

 

 

D. Module voltage output / Valve/

Verify battery voltage is at least 2.7 volts. Replace batteries if

 

Pilot solenoid ohms readings.

voltage is below 2.7.

 

 

 

60

Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev J • 06/08

Image 60
Contents Installation and Operation Models CD4236MR CD4842MRDirect Vent Gas Appliance What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents Installer GuideUser Guide Appliance Setup TroubleshootingReference Materials Gas Appliance Fireplace Limited Lifetime Warranty Limited Lifetime WarrantyListing and Code Approvals Requirements for the Commonwealth of Massachusetts Gas Fireplace Safety Operating InstructionsYour Fireplace Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceFor Your Safety Read Before Lighting Lighting Instructions IPILighting StandingPilot Frequently Asked Questions After Fireplace is LitMaintenance and Service Maintenance Tasks-HomeownerRemote Control Doors, Surrounds, FrontsMaintenance Tasks-Qualified Service Technician Getting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Framing and Clearances Select Appliance LocationModel # Construct the Appliance Chase ClearancesMantel and Wall Projections MantelsMantel Legs or Wall Projections Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsVent Diagrams Top Vent Horizontal TerminationOne Elbow Two 45 Elbows replacing One 90 Elbow Two ElbowsInstalled Vertically Three ElbowsTop Vent Vertical Termination No Elbow12 ft 3.66 m min 60 ft 18.29 m max Rear Vent Horizontal Termination One 45 ElbowTwo Elbows Rear Vent Vertical Termination Min Ft 1.83 m max 12 ft 3.66 m min 60 ft 18.29 m max Install Vertical Termination Baffle 17 Flat BaffleVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Installing Ceiling FirestopInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Convert from Top Vent to Rear VentOuter Collar, Remove Four Screws 11 Place Outer Collar on Rear of Appliance 16 Cover Plate-Replace Secure and Level the Appliance 20 Proper Positioning, Leveling And Securing Of AnInstall Vent Pipe Attach Pipe to the Firebox AssemblyAssemble Pipe Sections DVP Only Assemble Pipe SectionsAssemble Vent Sections SLP Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall RF4-8 SLP-FSInstall Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap InteriorGas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Standing Pilot Ignition System WiringIntellifire Ignition System Wiring Optional Accessories RequirementsElectrical Service and Repair WSK-MLT-HTLJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialCombustible Appliance Setup Install the Log Assembly Removing Fixed Glass AssemblyReplacing Fixed Glass Assembly Install Trim Install Clean Face ComponentsInstall Hood Install Top Latch CoverAir Shutter Setting Install Bottom Latch CoverInstall Firescreen Assembly Troubleshooting Standing Pilot Ignition SystemSymptom Possible Cause Corrective Action Intellifire Ignition System Will not ignite. If the pilot Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP Vent ComponentsBEK DVP-BEK2 DVP-TVHW DVP-TRAP DVP-HRC-SS Effective SL-2DVP AdapterService #22 Log/Grate AssemblyParts CD4842M Series Parts Service CD4842M SeriesOptional Components Model # Description Contact Information