Hearth and Home Technologies CD4842MILR, CD4842MR Symptom Possible Cause Corrective Action

Page 59

A. Standing Pilot Ignition System (continued)

Symptom

Possible Cause

Corrective Action

3. (Continued)

C. Failed valve.

Turn the valve knob to the ON position. Place the ON/OFF switch

 

 

in the ON position. Check the millivolt meter a the thermopile

 

 

terminals. The millivolt meter should read greater than 125mV. If the

 

 

reading is acceptable, and if the burner does not come on, replace

 

 

the gas valve.

 

 

 

 

D. Plugged burner orifice.

Check the burner orifice for stoppage. Remove stoppage.

 

 

 

 

E. Wall switch or wires.

Follow the corrective action in Symptom and Possible Cause 1.a

 

 

above. Check the switch and wiring.

4. Frequent pilot outage

A. Pilot flame may be too high or

Clean thermocouple and adjust the pilot flame for proper flame

problem.

too low, or blowing out (high

impingement. Follow lighting instructions carefully.

 

pressure), causing pilot safety

 

 

to drop out.

 

5. The pilot and main

A. No LP in tank.

Check the LP (propane) tank. Refill the fuel tank.

burner extinguish while in

 

 

B. Improper gas inlet pressure.

Verify with manometer. NG should read 5-14 inches w.c. LP should

operation.

 

read 10-14 inches w.c.

 

 

 

C. Inner vent pipe leaking exhaust

Check venting system for damage. Replace/repair improperly

 

gases back into the system.

assembled pipe sections.

 

 

 

 

D. Glass installed improperly.

Check to ensure glass is installed properly. Replace glass panel

 

 

assembly.

 

E. Failed thermopile or

Replace pilot if necessary.

 

thermocouple.

 

 

F. Improper vent cap installation.

Check for proper installation and freedom from debris or blockage.

 

 

 

6. Glass soots.

A. Flame impingement.

Adjust the log set so that the flame does not excessively impinge on

 

 

it. Refer to log instructions.

 

B. Improper air shutter setting.

Refer to manual for shutter set points. Ensure that set point is

 

 

correct for appliance/gas type. If unit has adjustable shutter, it may

 

 

be necessary to increase shutter opening.

 

C. Debris around air shutter.

Inspect the opening at the base of the burner. NO MATERIAL

 

 

SHOULD BE PLACED IN THIS OPENING.

7. Flame burns blue and lifts

A. Insufficient oxygen being

Ensure that the vent cap is installed properly and free of debris.

off burner.

supplied.

Ensure that the vent system joints are tight and have no leaks.

 

 

Ensure that no debris has been placed at the base of, or in the area

 

 

of the air holes in the center of the base pan beneath the burner.

 

 

 

 

 

Ensure that the glass is tightened properly on the unit, particularly

 

 

on top corners.

Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev J • 06/08

59

Image 59
Contents What to do if you smell gas Installation and OperationModels CD4236MR CD4842MR Direct Vent Gas ApplianceHomeowner Reference Information CongratulationsUser Guide Table of ContentsInstaller Guide Reference Materials Appliance SetupTroubleshooting Limited Lifetime Warranty Gas Appliance Fireplace Limited Lifetime WarrantyListing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalLighting Instructions IPI For Your Safety Read Before LightingPilot LightingStanding After Fireplace is Lit Frequently Asked QuestionsDoors, Surrounds, Fronts Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlMaintenance Tasks-Qualified Service Technician Typical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Model # Framing and ClearancesSelect Appliance Location Clearances Construct the Appliance ChaseMantel Legs or Wall Projections Mantel and Wall ProjectionsMantels Vent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Use of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyOne Elbow Vent DiagramsTop Vent Horizontal Termination Two Elbows Two 45 Elbows replacing One 90 ElbowThree Elbows Installed VerticallyNo Elbow Top Vent Vertical Termination12 ft 3.66 m min 60 ft 18.29 m max One 45 Elbow Rear Vent Horizontal TerminationTwo Elbows Rear Vent Vertical Termination Min Ft 1.83 m max 12 ft 3.66 m min 60 ft 18.29 m max 17 Flat Baffle Install Vertical Termination BaffleCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Ceiling Firestop Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Convert from Top Vent to Rear Vent Appliance PreparationOuter Collar, Remove Four Screws 11 Place Outer Collar on Rear of Appliance 16 Cover Plate-Replace 20 Proper Positioning, Leveling And Securing Of An Secure and Level the ApplianceAssemble Pipe Sections Install Vent PipeAttach Pipe to the Firebox Assembly Assemble Pipe Sections DVP OnlyAssemble Slip Sections Assemble Vent Sections SLP OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingSLP-FS Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components SLP only Interior Install Horizontal Termination CapGas Connection Gas InformationFuel Conversion Gas PressureOptional Accessories Requirements Wiring RequirementsStanding Pilot Ignition System Wiring Intellifire Ignition System WiringWSK-MLT-HTL Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationCombustible FinishingFacing Material Appliance Setup Replacing Fixed Glass Assembly Install the Log AssemblyRemoving Fixed Glass Assembly Install Top Latch Cover Install Trim Install Clean Face Components Install HoodInstall Firescreen Assembly Air Shutter SettingInstall Bottom Latch Cover Standing Pilot Ignition System TroubleshootingSymptom Possible Cause Corrective Action Intellifire Ignition System Will not ignite. If the pilot Reference Materials Appliance Dimension DiagramDVP Vent Components Vent Components DiagramsBEK DVP-BEK2 DVP-TVHW DVP-TRAP DVP-HRC-SS Effective Adapter SL-2DVPParts Service#22 Log/Grate Assembly CD4842M Series Parts CD4842M Series ServiceOptional Components Model # Description Contact Information