Hearth and Home Technologies SAPPH-D-CSB, 839-1390, 839-1440, 839-1460 Maintenance Tasks Inspect

Page 44

A Maintenance Tasks

Inspect

 

Maintenance Tasks

Doors

1.

Inspect for scratches, dents or other damage and repair as necessary.

 

2.

Verify no obstructions to air flow.

 

3.

Verify maintenance of proper clearance to combustible household objects.

Gasket Seal, Glass

1.

Inspect gasket seal and its condition.

Assembly and Glass

2.

Inspect glass for scratches and nicks that can lead to breakage when exposed to heat.

 

3.

Confirm there is no damage to glass or glass frame, Replace as necessary.

 

4.

Verify that latches engage properly and glass attachment components are intact and operat-

 

ing properly. Replace as necessary.

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be

 

removed.

Valve Compartment

1.

Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these

and Firebox Top

areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.

 

2.

Remove any foreign objects.

 

3.

Verify unobstructed air circulation.

Logs

1.

Inspect for broken, damaged, or missing logs. Replace as necessary.

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as neces-

 

sary.

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as neces-

 

sary.

 

2.

Replace appliance if firebox has been perforated.

Burner Ignition and

1.

Verify burner is properly secured and aligned with pilot or igniter.

Operation

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if

 

necessary. USE CAUTION WHEN CLEANING/HANDLING CERAMIC BURNER.

 

3.

Replace ember material with new dime-size and shape pieces. Do not block ports or obstruct

 

lighting paths.

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

5.

Inspect for lifting and other flame problems.

 

6.

Inspect orifice for soot, dirt or corrosion.

 

7.

Verify manifold and inlet pressures. Adjust regulator as required.

 

8.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

9.

Inspect thermocouple/thermopile sensor rod for soot, corrosion and deterioration. Clean with

 

emery cloth or replace as required.

 

10. Verify millivolt output. Replace as necessary.

Venting

1.

Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks,

 

fences or sheds) has been maintained.

 

4.

Inspect for corrosion or separation.

 

5.

Verify weather stripping, sealing and flashing remains intact.

Remote Controls

1.

Verify operation of remote.

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

Page 44

Quadra-Fire · Sapphire · 250-7233H

September 1, 2008

Image 44
Contents Do Discardnot What to do if you smell gasDo not Discard this Manual Welcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Design & Installation Considerations Tools will apply to every installationGetting Started Tools and Supplies NeededSelecting Appliance Location ClearancesTermination Locations 4Vent Termination Minimum ClearancesAlcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph Venting Guidelines Exception for Rear Vent KIT, Horizontal InstallationType a Up & Out Type B Rear Installations for Use with Rear Vent KitHorizontal Termination For installations requiring a vertical rise on the exterior 203mm Vertical Termination Direct Vent PipeStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a Up & Out Installations for Top Vent Configurations Existing Masonry ChimneyCut and bend flashing as needed to fit Sealant adhesive Flex Liner Flex Coupler Sheet Metal Screws Converting to LP Gas Gas InformationFuel Conversions Propane Natural GAS Gas Pressures PressureGas Connection Check for GAS LeaksRecommendation for Wire Connecting to the ApplianceStanding Pilot Ignition System Wiring Wire Size Max. LengthON/OFF Appliance Setup Remove Shipping MaterialsTop and Rear Vent Conversion At the TOP of the appliance, with exceptions notedReplace Burner Orifice for Horizontal Vent Configurations 059 53 DMS 096 41DMS Grille Cover Plate InstallationAccessories Front Installation Fronts are shipped attached to the faceFor Both Quartet and Solitaire Fronts Quartet Door AlignmentQty Description Hearth Legs InstallationPositioning the Logs Blower from front Glass Door Assembly Installation Blower InstallationMineral Wool Page Blower Damper Adjustment Shutter AdjustmentFor TOP or Rear Vent Installations Make adjustmentControls Operating InstructionsBefore Lighting Appliance For Your Safety Read Before Lighting Lighting ApplianceAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsQuadra-Fire · Sapphire · 250-7233H September 1 Vent Components DiagramMm inner pipe 6-5/8 in mm outer pipe Vent Components List HHT SL-PTermination Caps & Kits Sapphire Item # DescriptionService Parts cont’d Hinge Assembly Accessories Cast Parts Individual PiecesService and Maintenance Log Date of Service Performed By Description of ServiceWarranty Policy Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityHearth & Home Technologies Limited Warranty Cont’d Dealer Telephone SapphireContact Information