Termination Locations

 

 

 

A.4Vent Termination Minimum Clearances

 

 

 

 

 

20 in. (508mm)

 

WARNING

 

(minimum) to

 

 

Perpendicular

 

Fire Risk.

 

Wall (Gas Only)

 

 

 

 

Explosion Risk.

 

 

HORIZONTAL

Maintain vent clearance to combustibles

 

 

OVERHANG

 

 

 

as specified.

2 FT.

 

 

• Do not pack air space with insulation or other

20 IN.

 

MIN.

VERTICAL

 

materials.

 

LOWEST

WALL

 

 

Failure to keep insulation or other materials

 

DISCHARGE

 

 

OPENING

 

away from vent pipe may cause fire.

TERMINATION

 

 

CAP

 

 

 

 

 

 

 

 

X

 

 

 

12

Measure vertical clearances from this surface.

 

 

ROOF PITCH

 

 

 

IS X/12

 

 

H (MIN.) - MINIMUM HEIGHT FROM ROOF

 

 

TO LOWEST DISCHARGE OPENING

 

 

 

 

Roof Pitch

H (Min.) Ft.

 

 

 

 

Flat to 6/12 ......................................................... 1.0*

 

 

 

 

Over 6/12 to ........................................................7/12

1.25*

 

 

 

 

Over 7/12 to 8/12 ............................................... 1.5*

 

 

 

 

Over 8/12 to 9/12 ............................................... 2.0*

 

 

 

 

Over 9/12 to 10/12 ............................................. 2.5*

 

Measure horizontal clearances from this surface.

Over 10/12 to 11/12 ........................................... 3.25

 

(See Figure 4.4 for specific clearances.)

Over 11/12 to 12/12 ........................................... 4.0

 

Over 12/12 to 14/12 ........................................... 5.0

 

 

 

 

Figure 4.1 Termination Clearances

 

Over 14/12 to 16/12 ........................................... 6.0

 

Over 16/12 to 18/12 ........................................... 7.0

 

 

 

 

 

 

 

 

Over 18/12 to 20/12 ........................................... 7.5

 

Gas or Wood

 

Over 20/12 to 21/12 ........................................... 8.0

 

 

* 3 foot minimum in snow regions

 

 

Termination

 

 

 

20 in. (508mm)

 

 

 

 

 

 

Figure 4.3 Minimum Height from Roof to Lowest Discharge

 

 

 

(minimum) to

 

Gas

 

Perpendicular

Opening

 

 

 

18 in. Termination

Wall (Gas Only)

Figure 4.3 specifies minimum vent heights for various

 

(457mm)

 

 

 

 

A

 

pitched roofs.

 

 

 

 

 

 

 

 

 

Gas Termination

Wood & Fuel Oil Termination

 

 

 

A

6 in. (152mm)

 

20 in. (508mm)

 

 

 

Figure 4.2 Multiple Vertical Termination

 

 

 

Page 8

 

 

Quadra-Fire · Sapphire · 250-7233H

September 1, 2008

Image 8
Contents Do Discardnot What to do if you smell gasDo not Discard this Manual Welcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Design & Installation Considerations Tools will apply to every installationGetting Started Tools and Supplies NeededSelecting Appliance Location ClearancesTermination Locations 4Vent Termination Minimum ClearancesAlcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph Venting Guidelines Exception for Rear Vent KIT, Horizontal InstallationType a Up & Out Type B Rear Installations for Use with Rear Vent KitHorizontal Termination For installations requiring a vertical rise on the exterior 203mm Vertical Termination Direct Vent PipeStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a Up & Out Installations for Top Vent Configurations Existing Masonry ChimneyCut and bend flashing as needed to fit Sealant adhesive Flex Liner Flex Coupler Sheet Metal Screws Converting to LP Gas Gas InformationFuel Conversions Propane Natural GAS Gas Pressures PressureGas Connection Check for GAS LeaksRecommendation for Wire Connecting to the ApplianceStanding Pilot Ignition System Wiring Wire Size Max. LengthON/OFF Appliance Setup Remove Shipping MaterialsTop and Rear Vent Conversion At the TOP of the appliance, with exceptions notedReplace Burner Orifice for Horizontal Vent Configurations 059 53 DMS 096 41DMS Grille Cover Plate InstallationAccessories Front Installation Fronts are shipped attached to the faceFor Both Quartet and Solitaire Fronts Quartet Door AlignmentQty Description Hearth Legs InstallationPositioning the Logs Blower from front Glass Door Assembly Installation Blower InstallationMineral Wool Page Blower Damper Adjustment Shutter AdjustmentFor TOP or Rear Vent Installations Make adjustmentControls Operating InstructionsBefore Lighting Appliance For Your Safety Read Before Lighting Lighting ApplianceAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsQuadra-Fire · Sapphire · 250-7233H September 1 Vent Components DiagramMm inner pipe 6-5/8 in mm outer pipe Vent Components List HHT SL-PTermination Caps & Kits Sapphire Item # DescriptionService Parts cont’d Hinge Assembly Accessories Cast Parts Individual PiecesService and Maintenance Log Date of Service Performed By Description of ServiceWarranty Policy Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityHearth & Home Technologies Limited Warranty Cont’d Dealer Telephone SapphireContact Information