C. Vent Components List

Description

HHT SL-P

Simpson

Selkirk®

Amerivent

Security

 

M= Multi Pack (6)

Dura-Vent ®

Direct-Temp

Direct ®

Secure Vent®

 

 

DirectVent Pro

 

 

 

4” Pipe Length, Galvanized

SLP4M

-

-

-

-

4” Pipe Length, Black

SLP4-BK

-

-

-

-

6” Pipe Length, Galvanized

SLP6M

46-DVA-06

4DT-6

-

SV4L6

6” Pipe Length, Black

SLP6-BK

46-DVA-06B

4DT-6B

-

SV4LB6

7” Pipe Length, Galvanized

-

-

-

4D7

-

7” Pipe Length, Black

-

-

-

4D7B

-

9” Pipe Length, Galvanized

-

46-DVA-09

4DT-9

-

-

9” Pipe Length, Black

-

46-DVA-09B

4DT-9B

-

-

12” Pipe Length, Galvanized

SLP12M

46-DVA-12

4DT-12

4D12

SV4L12

12” Pipe Length, Black

SLP12-BK

46-DVA-12B

4DT-12B

4D12B

SV4LB12

18” Pipe Length, Galvanized

-

46-DVA-18

4DT-18

-

-

18” Pipe Length, Black

-

46-DVA-18B

4DT-18B

-

-

24” Pipe Length, Galvanized

SLP24M

46-DVA-24

4DT-24

4D2

SV4L24

24” Pipe Length, Black

SLP24-BK

46-DVA-24B

4DT-24B

4D2B

SV4LB24

36” Pipe Length, Galvanized

SLP36M

46-DVA-36

4DT-36

4D3

SV4L36

36” Pipe Length, Black

SLP36-BK

46-DVA-36B

4DT-36B

4D3B

SV4LB36

48” Pipe Length, Galvanized

SLP48M

46-DVA-48

4DT-48

4D4

SV4L48

48” Pipe Length, Black

SLP48-BK

46-DVA-48B

4DT-48B

4D4B

SV4LB48

Adjustable Length, 3”-6”, Black

SLP6A-BK

-

-

-

 

Adjustable Length, 3”-6”, Galvanized

SLP6AM

-

-

-

-

Adjustable Length, 3”-7”, Galvanized

-

46DVA-08A

-

-

-

Adjustable Length, 3”-7”, Black

-

46DVA-08AB

-

-

-

Adjustable Length, 3”-12”, Black

SLP12A-BK

-

-

-

-

Adjustable Length, 3”-12”, Galvanized

SLP12AM

-

-

-

-

Adjustable Length, 3”-14.5”, Galvanized

-

46DVA-16A

-

-

-

Adjustable Length, 3”-14.5”, Black

-

46DVA-16AB

-

-

-

Adjustable Length, 7”, Galvanized

-

-

-

4D7A

-

Adjustable Length, 7”, Black

-

-

-

4F7AB

-

Adjustable Length, 11”-14”, Galvanized

-

-

4DT-AJ

-

-

Adjustable Length, 11”-14”, Black

-

-

4DT-AJB

-

-

Adjustable Length, 12”, Galvanized

-

4DTAJ12

-

4D12A

SV4LA12

Adjustable Length, 12”, Black

-

4DTAJ12-B

-

4D12AB

SV4LBA12

Adjustable Length, 16”, Galvanized

-

46DVA-16A

-

4D16A

-

Adjustable Length, 16”, Black

-

46DVA-16AB

-

-

-

Adjustable Length, 24”, Galvanized

-

-

-

-

SV4LA24

Adjustable Length, 24”, Black

-

-

-

-

SV4LBA24

2’ Flexible Pipe Length

SLP-FLEX-2

-

-

-

-

3’ Flexible Pipe Length

SLP-FLEX-3

-

-

-

-

5’ Flexible Pipe Length

SLP-FLEX-5

-

-

-

-

10’ Flexible Pipe Length

SLP-FLEX-10

-

-

-

-

3” x 35’ Flex Extension

-

2280

-

-

-

4” x 35’ Flex Extension

-

2281

-

-

-

45° Elbow, Galvanized

SLP45M

-

-

-

-

45° Elbow, Black

SLP45-BK

See Swivel

4DT-EL45B

4D45LB

SV4EBR45

45° Elbow, Swivel, Galvanized

-

46DVA-E45

-

-

SV4E45

September 1, 2008

Quadra-Fire · Sapphire · 250-7233H

Page 47

Image 47
Contents Do Discardnot What to do if you smell gasDo not Discard this Manual Welcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Tools and Supplies Needed Design & Installation ConsiderationsTools will apply to every installation Getting StartedClearances Selecting Appliance Location4Vent Termination Minimum Clearances Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsException for Rear Vent KIT, Horizontal Installation How to Use the Vent Graph Venting GuidelinesType a Up & Out Type B Rear Installations for Use with Rear Vent KitHorizontal Termination For installations requiring a vertical rise on the exterior 203mm Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Type a Up & Out Installations for Top Vent ConfigurationsCut and bend flashing as needed to fit Sealant adhesive Flex Liner Flex Coupler Sheet Metal Screws Converting to LP Gas Gas InformationFuel Conversions Propane Natural GAS Pressure Gas PressuresCheck for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringON/OFF At the TOP of the appliance, with exceptions noted Appliance SetupRemove Shipping Materials Top and Rear Vent ConversionReplace Burner Orifice for Horizontal Vent Configurations 059 53 DMS 096 41DMS Grille Cover Plate InstallationAccessories Quartet Door Alignment Front InstallationFronts are shipped attached to the face For Both Quartet and Solitaire FrontsQty Description Hearth Legs InstallationPositioning the Logs Blower from front Glass Door Assembly Installation Blower InstallationMineral Wool Page Blower Make adjustment Damper AdjustmentShutter Adjustment For TOP or Rear Vent InstallationsControls Operating InstructionsBefore Lighting Appliance Lighting Appliance For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramQuadra-Fire · Sapphire · 250-7233H September 1 Vent Components DiagramMm inner pipe 6-5/8 in mm outer pipe HHT SL-P Vent Components ListTermination Caps & Kits Item # Description SapphireService Parts cont’d Hinge Assembly Cast Parts Individual Pieces AccessoriesDate of Service Performed By Description of Service Service and Maintenance LogCONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Dealer Telephone SapphireContact Information