Hearth and Home Technologies SAPPH-D-CWL Gas Information, Fuel Conversions, Converting to LP Gas

Page 23

6Gas Information

A.Fuel Conversions

Before making gas connections ensure that the appliance being installed is compatible with the available gas type.

Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a quali- fied technician using Hearth & Home Technologies specified and approved parts.

1. Converting to LP Gas

NOTE: Gas conversions should only be performed by a qualified service person, and/or where required by state and local codes, licensed installer/service technician. In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.

KIT CONTENTS: Replacement orifice; replacement pilot injector; valve regulator; and conversion label.

TOOLS REQUIRED: Power drill (a 90° handle is help- ful); #2 Phillips bit; 5/32" Allen wrench; 5/8" open end wrench.

IMPORTANT NOTE! The orifice supplied with this con- version kit is for TOP VENT MODELS ONLY. If your stove was fitted with the rear vent kit, the correct conversion orifice was supplied WITH THE REAR VENT KIT.

Figure 6.1 Remove front (if installed), glass, and logs (if installed.) Using the #2 Phillips screwdriver remove the two

(2)1/4" x 20 screws securing the burner as indicated. Lift burner out of firebox.

Figure 6.2 Remove the burner support by loosening the left screw on the pilot tower, and removing the two screws on the front side of the burner neck support.

Figure 6.3 Slide the burner neck support to the left. Pull off pilot hood and set aside.

Figure 6.4 Use a 5/32" Allen wrench to remove the pilot injector.

September 1, 2008

Quadra-Fire · Sapphire · 250-7233H

Page 23

Image 23
Contents Do Discardnot What to do if you smell gasDo not Discard this Manual Welcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Tools and Supplies Needed Design & Installation ConsiderationsTools will apply to every installation Getting StartedClearances Selecting Appliance Location4Vent Termination Minimum Clearances Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsException for Rear Vent KIT, Horizontal Installation How to Use the Vent Graph Venting GuidelinesType a Up & Out Type B Rear Installations for Use with Rear Vent KitHorizontal Termination For installations requiring a vertical rise on the exterior 203mm Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Type a Up & Out Installations for Top Vent ConfigurationsCut and bend flashing as needed to fit Sealant adhesive Flex Liner Flex Coupler Sheet Metal Screws Converting to LP Gas Gas InformationFuel Conversions Propane Natural GAS Pressure Gas PressuresCheck for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringON/OFF At the TOP of the appliance, with exceptions noted Appliance SetupRemove Shipping Materials Top and Rear Vent ConversionReplace Burner Orifice for Horizontal Vent Configurations 059 53 DMS 096 41DMS Grille Cover Plate InstallationAccessories Quartet Door Alignment Front InstallationFronts are shipped attached to the face For Both Quartet and Solitaire FrontsQty Description Hearth Legs InstallationPositioning the Logs Blower from front Glass Door Assembly Installation Blower InstallationMineral Wool Page Blower Make adjustment Damper AdjustmentShutter Adjustment For TOP or Rear Vent InstallationsControls Operating InstructionsBefore Lighting Appliance Lighting Appliance For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramQuadra-Fire · Sapphire · 250-7233H September 1 Vent Components DiagramMm inner pipe 6-5/8 in mm outer pipe HHT SL-P Vent Components ListTermination Caps & Kits Item # Description SapphireService Parts cont’d Hinge Assembly Cast Parts Individual Pieces AccessoriesDate of Service Performed By Description of Service Service and Maintenance LogCONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Dealer Telephone SapphireContact Information