Baxi Potterton BBU 15 HE manual Air Cowl Air Duct Collar Ribs Terminal Cap

Page 23

Air Cowl

Fig. 29

Air Duct

Collar

5 ribs

Fig. 28

Fig. 30

Fig. 31

Fig. 32

Terminal

Cap

Cement around Air Duct Collar &Cowl

Fig. 33

Fig. 34

© Baxi Heating UK Ltd 2009

7.0Installation

7.2Flue System (cont.)

16.Pass the air duct collar and air cowl over the 60mm flue duct (Fig. 28) and secure the collar to the closure plate with the screws supplied (Fig. 29). The air cowl will fit snugly over the collar.

17.Cut the protruding 60mm flue duct down so that 5 ribs are visible and fit the remaining 60mm lip seal into the first groove (Fig. 30). The flue duct adaptor can now be fitted in the same manner as the boiler adaptor (Fig. 31).

18.Fit the terminal cap over the flue duct adaptor and air cowl. Once the cap is clipped into position it cannot be removed easily without damage (Fig. 33).

19.Cement over the closure plate and air duct collar to a depth of approximately 100mm. Consideration should be given to the potential accumulation of snow in this area, and the possibility of it blocking the air inlet

(Fig. 34).

23

Image 23
Contents Baxi Bermuda BBU 15 HE 0086 Scheme Members only Installer Notification GuidelinesCodes of Practice, most recent version should be used Important Installation, Commissioning, Service & RepairLegislation Safe Manual Handling Contents Description ContentsIntroduction Layout Fig General LayoutFlue Kit 10m & 12.5m a Bermuda HE Cbbu 15 HE Technical DataThere is a drain cock supplied in the plumbing kit System DetailsWater Circulating Systems Treatment of Water Circulating SystemsStorage Systems PipeworkSystem Controls Sealed Systems Figs , 7 Sealed Systems Fireplace Opening & Surround Site RequirementsBuilders Opening Fig LocationNo Horizontal Runs are Permitted FlueElectrical Connection Gas Connection VentilationGas Supply Fig Electrical Supply FigCondensate Disposal Fig Condensate Drain GeneralFrom Boiler 500mm Min Total volume of the sump is 1.5 litresCondensate Disposal Condensate Pump OperationBoiler Internal Illustrated Wiring Diagram Boiler Internal WiringFlue System InstallationInitial Preparation Barb ‘C’ Clip Air Cowl Air Duct Collar Ribs Terminal Cap Electrical Connection Siting the BoilerWater Connections Gas ConnectionCommissioning the Boiler Completion & CommissioningCompletion Test Point Annual Servicing Annual ServicingAnnual Servicing Inspection Spark Generator Fig Electrode Assembly FigChanging Components Changing ComponentsBurner Spark Generator Plug Gas Feed Pipe Injector Fan FigBurner Fig Spark Generator Plug Electrode Fan InjectorGas Valve Fig Injector Gas Valve Earth WireNTC Fig Safety Thermostat FigFloat Switches Fig PCB FigFlue Sampling Point Display Control Knobs Setting the Gas ValveSetting the Gas Valve CO2 check Error Codes Fault FindingInitial Fault Finding Checks Go to section ‘A’ Error 110 flashingBurner lights Press the Service Reset Switch for 5 secondsSpark gap and position Check wiring Clean condensate drain systemX2 connector, is 230V AC across Terminals 1 Voltage at PCB X2 connector isReplace flame sensing electrode Replace Safety ThermostatShort Parts List 13.0 Short Parts ListPage Page Page GAS Boiler System Commissioning Checklist Date Energy Efficiency Checklist completed? Service RecordAfter Sales Service 0844 871 Warranty & ServiceSerial Number Date of Installation Installer Details name, address and contact numbers

BBU 15 HE specifications

The Baxi Potterton BBU 15 HE is a high-efficiency boiler designed to offer exceptional performance for both heating and hot water needs in residential settings. Known for its robust build quality and user-friendly features, this model is particularly favored for its versatility and reliability in various home environments.

One of the standout features of the Baxi Potterton BBU 15 HE is its compact size, making it suitable for installation in smaller spaces. Despite its small footprint, it delivers impressive outputs, making it ideal for homes with moderate heating demands. The boiler’s high efficiency rating ensures reduced energy consumption, leading to lower utility bills and a smaller carbon footprint.

Equipped with a powerful heat exchanger, the BBU 15 HE maximizes heat transfer, ensuring that households receive optimum warmth and hot water. With an output capacity of 15 kW, it can effectively heat a variety of living spaces while providing hot water on demand, making it a practical choice for families.

The boiler incorporates a number of advanced technologies that enhance its performance. One such feature is the built-in frost protection, which helps prevent the system from freezing during colder months. Additionally, the BBU 15 HE is designed for easy maintenance, featuring a simple access point for servicing, which can prolong the boiler’s lifespan and improve overall efficiency.

Safety is a top priority in any boiler installation, and the Baxi Potterton BBU 15 HE includes multiple safety features such as a pre-set temperature limit that prevents overheating and a pressure relief valve to manage excessive pressure within the system. These elements contribute to a safer home environment, providing peace of mind for homeowners.

Furthermore, the boiler is designed to operate quietly, minimizing disruptions in the home when heating systems are active. This is an important factor for many households where comfort is a priority.

In summary, the Baxi Potterton BBU 15 HE is a compact, efficient, and reliable boiler that provides an optimal solution for home heating and hot water needs. Its advanced features, safety systems, and user-friendly design make it a popular choice among homeowners, ensuring a cozy and comfortable living environment. Whether for a new installation or a replacement unit, this boiler stands out as a highly effective option in the market.