Hearth and Home Technologies SANTAFE-B1 Convection Blower Replacement, Exhaust Blower Replacement

Page 33

Santa Fe Pellet Stove

R

C. Blower Replacement

1.Convection Blower Replacement

a.Turn down the thermostat, let appliance completely cool and then unplug appliance before servicing.

b.The Convection Blower is located on the floor at the rear of the appliance.

c.Remove the right lower side curtain by releasing bracket from attachment holes in the back and then swing it to the front and lift off of the appliance. When re-installing flex curtain to re-attach. Figure 33.1.

d.Cut the tie wire holding the wires togehter and then dis- connect the yellow and purple wires.

e.Re-install in reverse order.

f.Attach new tie wire to hold wires together.

Remove lower right side curtain

Back of Stove

Flex curtain and snap brackets into attachment holes

Figure 33.1

Exhaust

Blower

Convection

Pull blower up of the locating

Blower

pins and pull towards you.

 

Figure 33.2

2.Exhaust Blower Replacement

a.Turn down the thermostat, let appliance completely cool and then unplug appliance before servicing.

b.Remove both lower side curtains. Figure 33.1.

c.Remove the lower rear screen and lay flat, leaving all wires still attached.

d.Remove the upper rear screen from the appliance by removing 2 screws at the top, 1 in the center and 2 screws on the sides at the top. Leave both upper side curtains still hinged in place to the rear screen. Figure 33.3.

e.Remove the 2 screws holding the vacuum switch in place. Disconnect vacuum hose and blue and white wires from the vacuum switch.

f.Remove the 2 screws holding the junction box in place.

e. Disconnect the white and blue wires from the exhaust blower.

f.There is a removable plate on the exhaust blower. Using a 1/4” nutdriver loosen the 6 screws in the keyhole shaped holes and rotate the plate. Figure 33.4

g.Remove the exhaust blower and gasket.

i. Re-install in reverse order.

Remove 2 screws, 1 on each side

Junction Box

Metal Strip

inside Hopper

Screws

 

Tabs at bottom of upper rear screen

Lower Rear Screen

Figure 33.3

Figure 33.4

September 1, 2008

7001-142D

Page 33

Image 33
Contents Santa FE Pellet Stove Santa Fe Pellet Stove Serial Number Model NameLocation Back side of left side panel Table of Contents Listing and Code Approvals Getting Started Design, Installation & Location Fire Safety ConsiderationsAppliance Location Thermostat LocationInspect Appliance & Components and Pre-Use Check List Santa Fe Pellet Stove Tools And Supplies NeededAppliance Dimensions 3Dimensions and ClearancesSanta Fe Pellet Stove Clearances to Combustibles UL and ULC Exception for Horizontal Installations Santa Fe Pellet Stove Hearth Pad Requirements UL and ULCHearth Pad Requirements Venting Termination Requirements Chimney and Exhaust ConnectionPipe Selection Chart Santa Fe Pellet Stove Equivalent Feet of PipeExample of 3 Elbow-Rear Vent Termination Calculaton Alcove Venting SystemsStraight Out DegreeSanta Fe Pellet Stove Through The Wall Through The Wall & Vertical Santa Fe Pellet Stove VerticalAlternate Masonry MasonryMobile Home Outside Air Kit Instructions 7Appliance Set-UpSanta Fe Pellet Stove Top Vent Adapter Installation Rear Vent and Rear Vent to Top Vent Adapter InstallationInstalling the Top Vent Adapter Notch Thermocouple Cover Installing the Grille Installing the Trim RingIncluded in Kit 1 Grille Santa Fe Pellet Stove Thermostat Installation Fuel Size And Material General Operating Information Operating InstructionsFeed Rate Adjustment Instructions Fire CharacteristicsFeed Adjustment Control Rod Wing Nut Set Screw Santa Fe Pellet Stove Before Your First FireSanta Fe Pellet Stove Iginition Cycles Frequently Asked QuestionsTroubleshooting SymptionPossible Cause Corrective Action Page Page Maintaining & Servicing Your Appliance Quick Reference Maintenance ChartFrequency Daily Weekly Monthly Yearly Types of FuelCleaning Ash Pan Cleaning Firepot with Cleaning Rod & Firepot ScraperAsh Removal from Firebox Disposal of Ashes Frequency As neededCleaning Beneath Heat Exchanger Cleaning Heat Exchanger Chambers & Drop TubeCleaning Beneath Heat Exchanger Cont’d Cleaning the Exhaust PathCleaning Exhaust Blower Requires No Lubrication Cleaning the GlassCleaning Convection Blower Requires No Lubrication Door Latch InspectionImmediate Attention and Cleaning is Required Santa Fe Pellet Stove High Ash Fuel Content MaintenanceExhaust Blower Replacement Convection Blower ReplacementWing Nut Snap Disc #2 ReplacementIgniter Replacement Baffle & Brick Replacement Glass Replacement Reference Materials Wiring Harness See .1 below Vacuum SwitchSnap Disc #1 Convection Blower 110F Snap Disc #2 Fuel Delivery Interrupt 250FSanta Fe Pellet Stove Component Locations Description Part Number Santa Fe Pellet Stove Exploded ViewsDescription Nbr Item # Service Parts Description Part Nbr Santa Fe Pellet Stove Service Parts and AccessoriesLVGRL-SF-NL Accessory Description Part NumberDate of Service Performed By Description of Service Santa Fe Pellet Stove Service And Maintenance LogCONDITIONS, Exclusions & Limitation of Liability Santa Fe Pellet Stove Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d Telephone Contact Information