Hearth and Home Technologies SANTAFE-B1 owner manual Chimney and Exhaust Connection

Page 10

 

R

Santa Fe Pellet Stove

 

 

 

 

 

 

 

 

4

Vent Information

 

 

 

 

 

A.Chimney and Exhaust Connection

1.Chimney & Connector: Use 3 or 4 inch (76-102mm) diameter type "L" or "PL" venting system. It can be vented vertically or horizontally.

2.Mobile Home: Approved for all Listed pellet vent. If using the 3 inch (76mm) vertical Top Vent Adapter Kit or the 3 to 6 inch (76-152mm) Top Vent Offset Adapter, use Listed double wall flue connector. A Quadra-Fire Outside Air Kit must be used with manufactured home installations.

3.Residential: The 3 inch (76mm) vertical Top Vent Adapter Kit and the 3 to 6 inch (76-152mm) Top Vent Offset Adapter are tested to use 24 gauge single wall flue connector or Listed double wall flue connector to Class A Listed metal chimneys, or masonry chimneys meeting Internationalt Conference of Building Officials (ICBO) standards for solid fuel appliances.

4.InSTALL vent at clearances specified by the vent manufacturer.

5.Secure exhaust venting system to the appliance with at least 3 screws. Also secure all connector pipe joints with at least 3 screws through each joint.

B. Venting Termination Requirements

CAUTION

Do not terminate vent in any enclosed or semi-enclosed area such as a carport, garage, attic, crawl space, under a sun deck or porch, narrow walkway or closely fenced area, or any location that can build up a concentration of fumes such as a stairwell, covered breezeway, etc.

1. Termination must exhaust above air inlet elevation. It is recommended that at least 60 inches (1524mm) of verti- cal pipe be installed when appliance is vented directly through a wall. This will create a natural draft, which will help prevent the possibility of smoke or odor venting into the home during a power outage. It will also keep exhaust from causing a nuisance or hazard by exposing people or shrubs to high temperatures. The safest and preferred venting method is to extend the vent vertically through the roof.

2. Distance from doors and opening windows, or gravity or ventilation air inlets into building:

a.Not less than 48 inches (1219mm) below;

b.Not less than 48 inches (1219mm) horizontally from;

c.Not less than 12 inches (305mm) above.

NOTE: All pipe must be welded seam pipe whenever possible. Seal pipe joints with high temperature silicone (500°F [260°C] minimum rated only).

NOTE: If burning shelled field corn, you must use approved venting specifically designed for corn. Follow the instructions from the venting manufacturer.

WARNING

Fire Hazard.

Only LISTED venting components may be used.

NO OTHER vent components may be used. Substitute or damaged vent components may impair safe operation.

WARNING

Vent surfaces get HOT, can cause burns if touched. Noncombustible shielding or guards may be required.

3. Distance from permanently closed windows;

a.Not less than 12 inches (305mm) below; horizontally from or above.

4. Distance between bottom of termination and grade should be 12 inches (305mm) minimum. This is conditional upon plants in the area, and nature of grade surface. The grade surface must be a non-combustible material (i.e., rock, dirt). The grade surface must not be lawn. Distance between bottom of termination and public walkway should be 84 inches (2134mm) minimum.

5. Distance to combustible materials must be 24 inches (610mm) minimum. This includes adjacent buildings, fences, protruding parts of the structure, roof overhang, plants and shrubs, etc.

6.Termination Cap Location (Home Electrical Service)

Side-to-side clearance is to be the same as minimum clearance to vinyl inside corners.

Clearance of a termination cap below electrical service shall be the same as minimum clearance to vinyl sof- fits.

Clearance of a termination cap above electrical service will be 12 inches minimum.

Location of the vent termination must not obstruct or interfere with access to the electrical service.

Page 10

7001-142D

September 1, 2008

Image 10
Contents Santa FE Pellet Stove Serial Number Model Name Santa Fe Pellet StoveLocation Back side of left side panel Table of Contents Listing and Code Approvals Appliance Location Design, Installation & Location Fire Safety ConsiderationsGetting Started Thermostat LocationSanta Fe Pellet Stove Tools And Supplies Needed Inspect Appliance & Components and Pre-Use Check List3Dimensions and Clearances Appliance DimensionsSanta Fe Pellet Stove Clearances to Combustibles UL and ULC Santa Fe Pellet Stove Hearth Pad Requirements UL and ULC Exception for Horizontal InstallationsHearth Pad Requirements Chimney and Exhaust Connection Venting Termination RequirementsSanta Fe Pellet Stove Equivalent Feet of Pipe Pipe Selection ChartExample of 3 Elbow-Rear Vent Termination Calculaton Venting Systems AlcoveDegree Straight OutSanta Fe Pellet Stove Through The Wall Santa Fe Pellet Stove Vertical Through The Wall & VerticalMasonry Alternate MasonryMobile Home 7Appliance Set-Up Outside Air Kit InstructionsRear Vent and Rear Vent to Top Vent Adapter Installation Santa Fe Pellet Stove Top Vent Adapter InstallationInstalling the Top Vent Adapter Notch Thermocouple Cover Installing the Trim Ring Installing the GrilleIncluded in Kit 1 Grille Santa Fe Pellet Stove Thermostat Installation Operating Instructions Fuel Size And Material General Operating InformationFeed Adjustment Control Rod Wing Nut Set Screw Fire CharacteristicsFeed Rate Adjustment Instructions Santa Fe Pellet Stove Before Your First FireFrequently Asked Questions Santa Fe Pellet Stove Iginition CyclesSymption TroubleshootingPossible Cause Corrective Action Page Page Frequency Daily Weekly Monthly Yearly Quick Reference Maintenance ChartMaintaining & Servicing Your Appliance Types of FuelAsh Removal from Firebox Cleaning Firepot with Cleaning Rod & Firepot ScraperCleaning Ash Pan Disposal of Ashes Frequency As neededCleaning Beneath Heat Exchanger Cont’d Cleaning Heat Exchanger Chambers & Drop TubeCleaning Beneath Heat Exchanger Cleaning the Exhaust PathCleaning Convection Blower Requires No Lubrication Cleaning the GlassCleaning Exhaust Blower Requires No Lubrication Door Latch InspectionSanta Fe Pellet Stove High Ash Fuel Content Maintenance Immediate Attention and Cleaning is RequiredConvection Blower Replacement Exhaust Blower ReplacementSnap Disc #2 Replacement Wing NutIgniter Replacement Baffle & Brick Replacement Glass Replacement Reference Materials Snap Disc #1 Convection Blower 110F Vacuum SwitchWiring Harness See .1 below Snap Disc #2 Fuel Delivery Interrupt 250FSanta Fe Pellet Stove Component Locations Santa Fe Pellet Stove Exploded Views Description Part NumberDescription Nbr Santa Fe Pellet Stove Service Parts and Accessories Item # Service Parts Description Part NbrAccessory Description Part Number LVGRL-SF-NLSanta Fe Pellet Stove Service And Maintenance Log Date of Service Performed By Description of ServiceSanta Fe Pellet Stove Warranty Policy CONDITIONS, Exclusions & Limitation of LiabilityHearth & Home Technologies Limited Warranty Cont’d Contact Information Telephone