R
Santa Fe Pellet Stove
Reference Materials
E
a. The control box is located on upper right side of appliance, behind the right side panel and above the vacuum switch.
b. There is a light located inside of the control box. The internal light will turn green when the appliance has reached a temperature of 200οF (93°C) in the firepot. and will turn red when it reaches 600oF (315°C).
c. There is also an internal blue light located in the upper left corner of the control box. When you plug in the appliance the blue light will automatically start blinking 6 times in a row for 60 seconds and then will stop.
When describing the location of a component, it is always AS YOU FACE THE FRONT OF THE APPLIANCE.
7.Heat Exchangers
The heat exchangers transfer hot air from the exhaust system into convecton air. Remove the stainless steel top baffle to access the heat exchangers. There are 2 clean out rods located under the heat exchangers.
8. Heat Output Switch
The heat output switch is located on the upper right rear panel. The function of the heat ouput switch is to regulate the burn rates; low, medium and high settings.
9.Igniter
NOTE:
Do NOT open the control box. This will void the warranty. If you need to plug in or remove the control box you must first unplug the appliance.
2.Convection Blower
The convection blower is mounted at the bottom rear of the appliance. There are 2 impellers, one on each side of the motor. The convection blower pushes heated air through the heat exchange system into the room.
3.Exhaust Blower
The exhaust blower is mounted on the right side of the appliance. The exhaust blower is designed to pull the exhaust from the appliance and push it out through the venting system.
4.Feed System
The feed system is located on the right side of the appliance and can be removed as an entire assembly. The assembly includes the feed motor, mounting bracket, bearing and feed spring (auger). The hollow feed spring (auger) pulls pellets up the feed tube from the hopper area and drops them down the feed chute into the firepot.
5.Firepot
The firepot is made of high quality ductile iron and has a cleaning
6.Fuse
The fuse is located on the front of the junction box next to the red call light. The fuse will blow should a short occur and shut off power to the appliance.
The igniter is mounted on the base of the firepot. Combustion air travels over the red hot igniter creating super heated air that ignites the pellets.
10.Junction Box And Wiring Harness
The junction box is located on the right side of the appliance, behind the right side panel. The junction box and wiring harness are replaced as one component.
11.Power Supply
The power outlet is located behind the control box on the back of the appliance, lower left corner. Check the wall receptacle for 120 volt, 60 Hz (standard current). Make sure the outlet is grounded and has the correct polarity. A good surge protector is recommended.
12.Red Call Light
The red call light is on the side of the junction box, next to the fuse. The function of the red call light is to indicate that the thermostat is calling for heat.
13.Reset Button
The reset button is located on the back of the appliance in the upper right corner below the heat output control switch. The function of the button is to momentarily open the thermostat circuit, which restarts the system.
14.Thermocouple
The thermocouple is located on top of the firepot inside the thermocouple cover (ceramic protection tube). The thermocouple sends a millivolt signal to the control box indicating the preset temperatures of the green and red lights have been obtained.
15.Thermostat
The appliance is designed to run on a 12 volt AC thermostat. The heat anticipator should be set on the lowest setting available.
Page 38 | September 1, 2008 |