R
Santa Fe Pellet Stove
B. Clearances to Combustibles (UL and ULC)
A C B
Alcove Installation | Inches | Millimeters |
Minimum Alcove Height | 43 | 1092 |
Minimum Alcove Side Wall | 6 | 152 |
Minimum Alcove Width | 38 | 965 |
Maximum Alcove Depth | 36 | 914 |
C
Straight Back Against | Inches | Millimeters | ||
Wall |
|
|
| |
A |
| Back Wall to Appliance | 2 | 51 |
B |
| Side Wall to Appliance | 6 | 152 |
|
|
| ||
Corner Installation | Inches | Millimeters | ||
C |
| Walls to Appliance | 2 | 51 |
I
J
C
L
Dimension to Corner | Inches | Millimeters | |
I | Flue Center Line | 217 | |
J | Back of Top Vent Adapter | 232 |
Installations with:
3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit
F | D |
| E |
G | H | |
H | ||
| ||
| G |
WARNING
Fire Risk.
Comply with all minimum clearances to combustibles as specified.
Failure to comply may cause house fire.
Vertical Installation | Inches | Millimeters | |
D | Back Wall to Flue Pipe | 3 | 76 |
E | Side Wall to Cast Top | 6 | 152 |
F | Back Wall to Appliance | 7 | 178 |
|
|
| |
Corner Installation | Inches | Millimeters | |
G | Walls to Appliance | 2 | 51 |
H | Side Wall to Flue Pipe | 3 | 76 |
NOTE:
•Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.
•Illustrations/diagrams are not drawn to scale.
•Actual installation may vary due to individual design preference.
Page | September 1, 2008 |