Santa Fe Pellet Stove
R
D. Igniter Replacement
Firepot |
Igniter |
Thumb Screw |
Figure 35.1
1.Shut down the appliance by turning down the thermostat and let the appliance completely cool down. After the appliance has cooled down, unplug it and remove the ash drawer.
2.The wire leads to the igniter are connected to the wire harness with 1/4 inch male / female spade connectors. Disconnect the spade connections and remove the igniter from the chamber. Loosen thumb screw and slide igniter out.
.Install new igniter into the chamber and tighten thumb screw.
4.Double check that the igniter wires are clear of any movement, i.e. ash drawer, firepot cleaning rod, cleaning slide plates, etc.
5.
E.Baffle & Brick Removal
1.Appliance must be completely cool.
2.Open door and locate the baffle at top of inside of firebox.
3.The baffle is secured to the right bracket. A tab on the baffle is inserted into a notch on the right bracket. Lift the baffle up, out of the notch and towards you. Figure 35.2. The left side of the baffle has a hook that rests on the top edge of the brick. This side will just lift off.
4.Remove right brick by pulling up and then towards you to expose the exhaust venting for cleaning. Figure 35.3.
Hook on
left sideTab on right side
Figure 35.2
Figure 35.3
September 1, 2008 | Page 35 |