SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
CONTROL BOARD DIAGNOSTIC LED INTERPRETATION AND
TROUBLESHOOTING
TEST 1 - 120 VAC CHECK TO WATER HEATER
Conditions:
No Green display “Power” LED on.
Plugs are in receptacles.
Supply power breaker is not “open”
On/Off heater switch is “On”.
Water Heater
Control
Ignition Control Board
TEST 1
120 Vac Check To Water Heater On Switch
Check for
115 V check to E13 terminal and 2B receptical.
If… | ...then |
|
|
voltage is not present from on/off switch- | check conditions above |
|
|
center black wire to ground | check wiring from switch to break box |
| |
power is present from center on/off | check power from on/off to ignition board term |
| |
terminal | E13. |
|
|
| check wiring from on/off. |
| |
voltage is not present at E13 to ground | to E13. |
|
|
| replace on/off switch. |
|
|
power is present at E13 | check power from E14 to heater control E2 |
| |
receptacle |
|
| |
|
|
| |
voltage is not present from heater control | check wiring from ignition control board E14 to |
| |
heater control receptacle E2. |
| ||
receptacle E2 black to ground |
| ||
replace ignition control board. |
| ||
|
| ||
power is present at E2 | green LED should be on. |
|
|
|
|
|
|
©2003 | 26 | Technical Training Department |
Ashland City, Tennessee