State Industries STC-074 specifications Conditions, Water Heater Control Ignition Control Board

Page 27

SBN TANK TYPE COMMERCIAL GAS WATER HEATER

SERVICE HANDBOOK

CONTROL BOARD DIAGNOSTIC LED INTERPRETATION AND

TROUBLESHOOTING

TEST 1 - 120 VAC CHECK TO WATER HEATER

Conditions:

ƒNo Green display “Power” LED on.

ƒPlugs are in receptacles.

ƒSupply power breaker is not “open”

ƒOn/Off heater switch is “On”.

Water Heater

Control

Ignition Control Board

TEST 1

120 Vac Check To Water Heater On Switch

ŒCheck for 115-125 VAC black wire to ground

Œ115 V check to E13 terminal and 2B receptical.

If…

...then

 

 

voltage is not present from on/off switch-

Œcheck conditions above

 

 

center black wire to ground

Œcheck wiring from switch to break box

 

power is present from center on/off

check power from on/off to ignition board term

 

terminal

E13.

 

 

 

Œcheck wiring from on/off. Left-outside terminal

 

voltage is not present at E13 to ground

to E13.

 

 

 

Œreplace on/off switch.

 

 

power is present at E13

check power from E14 to heater control E2

 

receptacle

 

 

 

 

 

voltage is not present from heater control

Œcheck wiring from ignition control board E14 to

 

heater control receptacle E2.

 

receptacle E2 black to ground

 

Œreplace ignition control board.

 

 

 

power is present at E2

green LED should be on.

 

 

 

 

 

 

©2003

26

Technical Training Department

Ashland City, Tennessee

Image 27
Contents Service Handbook Table of Contents SBN Service Handbook Introduction Custom Commercial Storage Tank Model Number Break Down QualificationsTop and Front Views of Minimum Clearances To Combustibles Installation ConsiderationsRequired Exterior Clearances Exterior ClearanceComb AIR Make-Up Air Direct Communication Not Direct Vent Make-Up Air Horizontal Ducts Make-Up Air Vertical DuctsAir for Combustion Flammable Items Contaminated AirGas Valve Outlet View Venting Atmospheric Multiple Heaters VentingNine Rules for Good Vents SBN Tank Type Commercial GAS Water Heater Service Handbook SBN Tank Type Commercial GAS Water Heater Service Handbook Multiple Gas Fired Tank-Type Heaters Type B GAS VentTechnical Dataventing Top View SequenceFront View of Water Heater SBN Tank Type Commercial GAS Water Heater Service Handbook HSI Integrated Ignition Control Board HSI Lower Front View of SBN Water HeaterECO Wiring DiagramElectrical Sequence of SBN Water Heater Operation PRE-SERVICE Checklist Water Heater Control Ignition Control Board ConditionsTest 2 Polarity Check Flash Codes of Diagnostic IndicatorTest 3 Continuity Check High Limit ECO Test 2 Polarity CheckIs not present Test 4 Upper Temperature Probe Continuity CheckTest 3 Continuity Check of High Limit ECO Is indicatedTest 5 Calling for Heat no Inducer Operation Water Heater ControlCheck to Inducer Test on Ignition Board 4 Pin Receptacle E4 VAC Check of Blower Prover/Low Gas Pressure Circuit Test 6 Inducer ON-NO IgnitionVoltage is not present between E4, Pin Test of Igniter and gas valve circuit Test 8 Igniter Heats no Main BurnerContinuity Check Of Gas Valve Coil Test 9 Igniter Heats no Main BurnerFlame Prover Circuit Check Test 10 Main Burner Ignition for Less than 5 SecondsIf… Then Test 11 Water Heater Shutting OFF below SettingDisplay Lights on Integrated Heater Control ECO SBN Tank Type Commercial GAS Water Heater Service Handbook Technical Training Department 120 154 180 199 200A 250A 275A 310A 366A 400A General Questions and Answers SBN Tank Type Commercial GAS Water Heater Service Handbook Draft Proving Pressure Switch Table