SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
TEST 9 - IGNITER HEATS – NO MAIN BURNER
Conditions:
Test 8 completed then:
Turn off power
Disconnect wires from gas valves
TEST 9
Continuity Check Of Gas Valve Coil
If… | ...then |
|
|
| check meter scale setting to read between 550 |
| |
meter reads 0 or 1 | and 650 Ohms |
|
|
| replace Gas Valve |
|
|
meter indicates pilot and main coil have | valve should be okay |
|
|
still no gas to main burner, then coil may be |
| ||
continuity |
| ||
stuck - Replace Valve |
|
| |
|
|
| |
|
|
|
|
©2003 | 34 | Technical Training Department |
Ashland City, Tennessee