SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
LED INDICATORS ON HOT SURFACE IGNITION (HSI)
USING FLASHING RED LED ON HSI (HOT SURFACE IGNITION)
| LED STATUS | INDICATION | ACTION TO BE TAKEN |
|
| 1 Flash | System is in lockout. | Interrupt power to |
|
|
|
| reset. Heater had not |
|
|
|
| sensed the flame – |
|
|
|
| check gas supply and |
|
|
|
| igniter condition. |
|
| 2 Flashes | Draft proving | Test for defective |
|
|
| (pressure) switch | switch or a |
|
|
| (closes at | pressurized room |
|
|
| inches W.C. negative | condition that may be |
|
|
| pressure) failed to | forcing air through the |
|
|
| open within 5 seconds | inducer. |
|
|
| at the end of the last |
|
|
|
| cycle. |
|
|
| 3 Flashes | Draft proving | Check the draft. |
|
|
| (pressure) switch | The low gas pressure |
|
|
| failed to close | switch closes at 5.2 inches W.C. |
|
|
| within 5 seconds after | may have remained open. |
|
|
| the inducer was | Verify the supply gas pressure |
|
|
| started. | while the gas is flowing. |
|
|
|
|
|
|
| 4 Flashes | Open on high | Check temperature |
|
| control operation. |
| ||
|
| temperature |
|
|
|
| limit switch |
|
|
|
| (ECO) |
|
|
| 6 Flashes | Verify that a |
| |
| check results |
| ||
|
| connection is | in “0” volts and a |
|
|
| indicating reversed | ground check |
|
|
| polarity. | results in |
|
|
|
|
|
|
|
|
|
|
|