State Industries STC-074 specifications Flash Codes of Diagnostic Indicator, Test 2 Polarity Check

Page 28

SBN TANK TYPE COMMERCIAL GAS WATER HEATER

SERVICE HANDBOOK

FLASH CODES OF DIAGNOSTIC INDICATOR

Conditions:

ƒPower On

ƒRed, heater control “Call for Heat” LED – on

ƒRed, ignition control board diagnostic LED – Flashing

ƒNote LED Flash Code before resetting heater.

LED Status

Indication

1

Flash

System is in lock out.

2

Flashes

Draft proving (pressure) switch failed to open within 5 seconds at the end of the last cycle.

 

 

 

3

Flashes

Draft proving (pressure) switch failed to close ( -2.1 inches of water column pressure) within 5

 

 

seconds after the inducer was started.

 

 

The low gas pressure switch )closes at 5.2" ± .04" w.c.) may have remained open.

 

 

 

4

Flashes

Open on high temperature limit switch (ECO).

6

Flashes

115-volt supply power connection is indicating reversed polarity.

7

Flashes

Flame sensor reads a low flame signal for more than 4.25 sec.

8

Flashes

No ignition sensed.

Continuous Flash

Continuous flame sensed for more than 5 seconds without gas valve being energized.

 

 

Continuous ON

Internal control board failure.

*Control system self adjusts to use a minimum voltage for ignition. Lower voltage results in lower igniter temperature which results in longer igniter life. Igniter voltage may vary from Nominal 80 VAC.

TEST 2 - POLARITY CHECK

Conditions:

 

ƒ No hot water

Display

ƒ Green “Power” LED is on.

 

ƒ Tank is more than 5° F

 

below temperature dial

 

setting.

 

ƒ Red ignition control board

 

diagnostic LED is flashing

 

6 times between pauses.

 

ƒ Red, diagnostic “Call for

 

Heat” LED-OFF.

 

LED’s

Continued on next page

Technical Training Department

27

©2003

Ashland City, Tennessee

Image 28
Contents Service Handbook Table of Contents SBN Service Handbook Introduction Qualifications Custom Commercial Storage Tank Model Number Break DownInstallation Considerations Top and Front Views of Minimum Clearances To CombustiblesExterior Clearance Required Exterior ClearancesComb AIR Make-Up Air Direct Communication Not Direct Vent Make-Up Air Vertical Ducts Make-Up Air Horizontal DuctsContaminated Air Air for Combustion Flammable ItemsGas Valve Outlet View Venting Venting Atmospheric Multiple HeatersNine Rules for Good Vents SBN Tank Type Commercial GAS Water Heater Service Handbook SBN Tank Type Commercial GAS Water Heater Service Handbook Type B GAS Vent Multiple Gas Fired Tank-Type HeatersTechnical Dataventing Sequence Top ViewFront View of Water Heater SBN Tank Type Commercial GAS Water Heater Service Handbook HSI Integrated Ignition Control Board Lower Front View of SBN Water Heater HSIWiring Diagram ECOElectrical Sequence of SBN Water Heater Operation PRE-SERVICE Checklist Conditions Water Heater Control Ignition Control BoardFlash Codes of Diagnostic Indicator Test 2 Polarity CheckTest 2 Polarity Check Test 3 Continuity Check High Limit ECOTest 4 Upper Temperature Probe Continuity Check Test 3 Continuity Check of High Limit ECOIs indicated Is not presentWater Heater Control Test 5 Calling for Heat no Inducer OperationCheck to Inducer Test on Ignition Board 4 Pin Receptacle E4 Test 6 Inducer ON-NO Ignition VAC Check of Blower Prover/Low Gas Pressure CircuitVoltage is not present between E4, Pin Test 8 Igniter Heats no Main Burner Test of Igniter and gas valve circuitTest 9 Igniter Heats no Main Burner Continuity Check Of Gas Valve CoilTest 10 Main Burner Ignition for Less than 5 Seconds Flame Prover Circuit CheckTest 11 Water Heater Shutting OFF below Setting If… ThenDisplay Lights on Integrated Heater Control ECO SBN Tank Type Commercial GAS Water Heater Service Handbook Technical Training Department 120 154 180 199 200A 250A 275A 310A 366A 400A General Questions and Answers SBN Tank Type Commercial GAS Water Heater Service Handbook Draft Proving Pressure Switch Table