SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
ELECTRICAL SEQUENCE OF SBN WATER HEATER OPERATION
120VAC
Power to Heater Green LED - On
Call for Heat
Green LED - On
Module Self Check
|
| Low Gas Pressure |
| Natural Gas Models Only | |||
|
| Switch is Closed |
| ||||
|
|
|
|
| |||
|
| Draft Proving Switch |
|
| |||
|
| Is Open |
|
|
|
|
|
|
| High Limit is Closed |
|
|
| ||
|
| Inducer On |
|
|
|
| |
|
| Blower Prover |
|
|
|
| |
Closes |
| ||||||
|
| Ignition Control Board – |
|
| |||
|
| 120 VAC |
|
|
|
|
|
Variable Voltage | HSI Warm Up |
|
|
|
| ||
20 seconds |
|
|
|
| |||
|
|
|
|
| |||
|
|
|
|
|
|
| |
|
| Gas Valve Open |
| 3 Second Trial |
|
| |
|
|
|
|
| HSI - Off |
|
|
|
|
| 3 Seconds to Prove |
|
| ||
|
|
| Flame After HSI - Off |
|
| ||
|
| Flame Proves |
|
| Minimum Millivolt for | ||
|
|
|
|
| 4.25 seconds | ||
|
|
|
|
|
|
| |
|
| Yes |
|
| No | Yes | No |
Tank Heated to Set Temperature | 20 Second Blower Purge | Flash 7 Times | |||||
|
|
|
| ||||
|
|
|
|
| 2 More Trials |
| 1 Hour Auto Reset |
|
|
|
|
|
|
| |
| Gas Valve – Off |
|
| To Prove Flame |
|
| |
Call for Heat LED - Off |
|
|
|
|
| ||
60 Second Blower Post Purge | Yes |
| No |
| |||
|
|
|
|
| |||
Blower Prover - Opens |
|
| Flash 8 Times On Diagnostic LED | ||||
|
|
|
|
| |||
Standby LED - On |
|
| Lock Out for 1 Hour | ||||
|
| Then Retry |
|
©2003 | 24 | Technical Training Department |
Ashland City, Tennessee