SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
TEST 7 - INDUCER ON – PROVER SWITCH AND LOW GAS SWITCH
CLOSED – NO IGNITER OPERATION
Conditions:
Power on
Plugs in receptacles
Inducer on
24V at ignition board E1, Pin 10
No Power to igniter Note: Flash code of LED
Check E4 pin 4 to Ground
Continuity Test
E4 Plug
Check E1 pin 10
24V
Check E4 pin 2 to Ground
TEST 7
Voltage check and continuity check of hot surface igniter circuit
Continuity check - Power off- Plug removed from E4 receptacles Nominal 80 VAC check - Plug in E4- Power "On"
If… | ...then |
|
|
continuity is not indicated between E4 | check wiring and connection from E4 plug to |
| |
HSI receiving plug |
|
| |
plug pin 2 to 4. |
|
| |
replace HSI Assembly |
|
| |
|
|
| |
continuity is present | resistance should be between 11 and 20 Ohms |
| |
at a temperature of 77°F |
|
| |
|
|
| |
voltage is not present between E4, Pin 2 | replace ignition board |
|
|
to ground |
|
| |
|
|
| |
voltage is present | continue |
|
|
voltage is not present between E4, Pin 4 | check wiring and plug connections to HSI |
| |
to ground | replace HSI |
|
|
voltage is present | note igntion board, Flash code LED |
| |
HSI should work |
|
| |
|
|
| |
|
|
|
|
©2003 | 32 | Technical Training Department |
Ashland City, Tennessee