SBN TANK TYPE COMMERCIAL GAS WATER HEATER

SERVICE HANDBOOK

TEST 11 - WATER HEATER SHUTTING OFF BELOW SETTING

Conditions:

ƒMain burner ignited

ƒStored water is below temperature setting more than 5° F (Tank Average).

ƒPower off

ƒPlug disconnected from heater control board receptacle E3 and E4

Red

Black Red

TEST 11

Water Temperature Circuit Check - Continuity

If…

...then

 

 

continuity check pin to pin of lower

Œsee Test 4

 

 

temperature probe shows 1 or 0 (E4)

Œcheck wiring and plug connections to heater

 

 

control board receptacle E4

 

 

Œreplace lower temperature probe

 

continuity check red wire pin to red wire pin

Œsee Test 4

 

 

on upper temperature sensor shows 1 or 0

Œcheck wiring and plug connections to heater

 

(E3)

control board receptacle

 

 

 

Œreplace upper temperature probe

 

all above checks are okay

replace the water heater control.

 

 

 

 

 

©2003

36

Technical Training Department

Ashland City, Tennessee

Image 37
Contents Service Handbook Table of Contents SBN Service Handbook Introduction Custom Commercial Storage Tank Model Number Break Down QualificationsTop and Front Views of Minimum Clearances To Combustibles Installation ConsiderationsRequired Exterior Clearances Exterior ClearanceComb AIR Make-Up Air Direct Communication Not Direct Vent Make-Up Air Horizontal Ducts Make-Up Air Vertical DuctsAir for Combustion Flammable Items Contaminated AirGas Valve Outlet View Venting Atmospheric Multiple Heaters VentingNine Rules for Good Vents SBN Tank Type Commercial GAS Water Heater Service Handbook SBN Tank Type Commercial GAS Water Heater Service Handbook Multiple Gas Fired Tank-Type Heaters Type B GAS VentTechnical Dataventing Top View SequenceFront View of Water Heater SBN Tank Type Commercial GAS Water Heater Service Handbook HSI Integrated Ignition Control Board HSI Lower Front View of SBN Water HeaterECO Wiring DiagramElectrical Sequence of SBN Water Heater Operation PRE-SERVICE Checklist Water Heater Control Ignition Control Board ConditionsTest 2 Polarity Check Flash Codes of Diagnostic IndicatorTest 3 Continuity Check High Limit ECO Test 2 Polarity CheckTest 3 Continuity Check of High Limit ECO Test 4 Upper Temperature Probe Continuity CheckIs indicated Is not presentWater Heater Control Test 5 Calling for Heat no Inducer OperationCheck to Inducer Test on Ignition Board 4 Pin Receptacle E4 VAC Check of Blower Prover/Low Gas Pressure Circuit Test 6 Inducer ON-NO IgnitionVoltage is not present between E4, Pin Test of Igniter and gas valve circuit Test 8 Igniter Heats no Main BurnerContinuity Check Of Gas Valve Coil Test 9 Igniter Heats no Main BurnerFlame Prover Circuit Check Test 10 Main Burner Ignition for Less than 5 SecondsIf… Then Test 11 Water Heater Shutting OFF below SettingDisplay Lights on Integrated Heater Control ECO SBN Tank Type Commercial GAS Water Heater Service Handbook Technical Training Department 120 154 180 199 200A 250A 275A 310A 366A 400A General Questions and Answers SBN Tank Type Commercial GAS Water Heater Service Handbook Draft Proving Pressure Switch Table