SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
TEST 11 - WATER HEATER SHUTTING OFF BELOW SETTING
Conditions:
Main burner ignited
Stored water is below temperature setting more than 5° F (Tank Average).
Power off
Plug disconnected from heater control board receptacle E3 and E4
Red
Black Red
TEST 11
Water Temperature Circuit Check - Continuity
If… | ...then |
|
|
continuity check pin to pin of lower | see Test 4 |
|
|
temperature probe shows 1 or 0 (E4) | check wiring and plug connections to heater |
| |
| control board receptacle E4 |
| |
| replace lower temperature probe |
| |
continuity check red wire pin to red wire pin | see Test 4 |
|
|
on upper temperature sensor shows 1 or 0 | check wiring and plug connections to heater |
| |
(E3) | control board receptacle |
|
|
| replace upper temperature probe |
| |
all above checks are okay | replace the water heater control. |
| |
|
|
|
|
©2003 | 36 | Technical Training Department |