SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
TEST 10 - MAIN BURNER IGNITION FOR LESS THAN 5 SECONDS
Conditions:
Power On – plug connected
Main Burner ignites for approximately 5 seconds then goes out.
Tests 8 and 9 completed
Note flash code on ignition board LED.
Hot Surface Igniter
Pin 2
Main Burner
E1, Pin 2 - From Flame Proving Rod
(Illustration of low NOx burner)
TEST 10
Flame Prover Circuit Check
If… | ...then |
|
no extended main burner igntion | check wiring and plug connections of HSI assembly | |
| ||
| plug and ignition board receptacles E1, Pin 2 |
|
| check that HSI assembly is not cracked or dirty |
|
| check that flame prover will be in main flame |
|
| replace HSI assembly |
|
|
|
|
still no extended main burner ignition | replace ignition control board |
|
|
|
|