State Industries STC-074 specifications Test 10 Main Burner Ignition for Less than 5 Seconds

Page 36

SBN TANK TYPE COMMERCIAL GAS WATER HEATER

SERVICE HANDBOOK

TEST 10 - MAIN BURNER IGNITION FOR LESS THAN 5 SECONDS

Conditions:

ƒPower On – plug connected

ƒMain Burner ignites for approximately 5 seconds then goes out.

ƒTests 8 and 9 completed

ƒNote flash code on ignition board LED.

Hot Surface Igniter

Pin 2

Main Burner

E1, Pin 2 - From Flame Proving Rod

(Illustration of low NOx burner)

TEST 10

Flame Prover Circuit Check

If…

...then

 

no extended main burner igntion

Œcheck wiring and plug connections of HSI assembly

 

 

plug and ignition board receptacles E1, Pin 2

 

 

Œcheck that HSI assembly is not cracked or dirty

 

 

Œcheck that flame prover will be in main flame

 

 

Œreplace HSI assembly

 

 

 

 

still no extended main burner ignition

replace ignition control board

 

 

 

 

Technical Training Department

35

©2003

 

 

Ashland City, Tennessee

Image 36
Contents Service Handbook Table of Contents SBN Service Handbook Introduction Qualifications Custom Commercial Storage Tank Model Number Break DownInstallation Considerations Top and Front Views of Minimum Clearances To CombustiblesExterior Clearance Required Exterior ClearancesComb AIR Make-Up Air Direct Communication Not Direct Vent Make-Up Air Vertical Ducts Make-Up Air Horizontal DuctsContaminated Air Air for Combustion Flammable ItemsGas Valve Outlet View Venting Venting Atmospheric Multiple HeatersNine Rules for Good Vents SBN Tank Type Commercial GAS Water Heater Service Handbook SBN Tank Type Commercial GAS Water Heater Service Handbook Type B GAS Vent Multiple Gas Fired Tank-Type HeatersTechnical Dataventing Sequence Top ViewFront View of Water Heater SBN Tank Type Commercial GAS Water Heater Service Handbook HSI Integrated Ignition Control Board Lower Front View of SBN Water Heater HSIWiring Diagram ECOElectrical Sequence of SBN Water Heater Operation PRE-SERVICE Checklist Conditions Water Heater Control Ignition Control BoardFlash Codes of Diagnostic Indicator Test 2 Polarity CheckTest 2 Polarity Check Test 3 Continuity Check High Limit ECOTest 4 Upper Temperature Probe Continuity Check Test 3 Continuity Check of High Limit ECOIs indicated Is not presentTest 5 Calling for Heat no Inducer Operation Water Heater ControlCheck to Inducer Test on Ignition Board 4 Pin Receptacle E4 Test 6 Inducer ON-NO Ignition VAC Check of Blower Prover/Low Gas Pressure CircuitVoltage is not present between E4, Pin Test 8 Igniter Heats no Main Burner Test of Igniter and gas valve circuitTest 9 Igniter Heats no Main Burner Continuity Check Of Gas Valve CoilTest 10 Main Burner Ignition for Less than 5 Seconds Flame Prover Circuit CheckTest 11 Water Heater Shutting OFF below Setting If… ThenDisplay Lights on Integrated Heater Control ECO SBN Tank Type Commercial GAS Water Heater Service Handbook Technical Training Department 120 154 180 199 200A 250A 275A 310A 366A 400A General Questions and Answers SBN Tank Type Commercial GAS Water Heater Service Handbook Draft Proving Pressure Switch Table