SBN TANK TYPE COMMERCIAL GAS WATER HEATER

SERVICE HANDBOOK

TEST 3 - CONTINUITY CHECK OF HIGH LIMIT (ECO)-CONTINUED

TEST 3

Continuity check of ECO (energy cut-off, high limit)

Black to Black wires of upper probe. Power is off.

If…

 

...then

continuity

is indicated

opens at 203° F; closes at 193° F. If water is

below 193° F, continuity is correct.

 

 

continuity

is not present

replace ECO sensor, if water temperature is

below 193° F.

 

 

 

 

reset status LED should be on.

water is less than 120° F

replace heater control if control will not manually

 

 

reset.

TEST 4 - UPPER TEMPERATURE PROBE CONTINUITY CHECK

Conditions:

ƒPower On - Water below tempera- ture set point.

ƒRed, heater control “Reset Status”

LED-OFF

ƒ“Call For Heat” LED off.

Ohms Resistance Table

° F

Ohms

70°

11,884

120°

3,759

140°

2,488

180°

1,169

TEST 4

Upper Temperature probe continuity check

Red wire to red wire - Turn supply power "Off" for this test

If…

...then

 

test indicates no continuity

replace probe.

 

 

probe should be okay (also verify Ohms

 

continuity is indicated

resistance for water temperature). (Reading will

 

be approximate.)

 

 

 

 

Technical Training Department

29

©2003

 

 

Ashland City, Tennessee

Image 30
Contents Service Handbook Table of Contents SBN Service Handbook Introduction Qualifications Custom Commercial Storage Tank Model Number Break DownInstallation Considerations Top and Front Views of Minimum Clearances To CombustiblesExterior Clearance Required Exterior ClearancesComb AIR Make-Up Air Direct Communication Not Direct Vent Make-Up Air Vertical Ducts Make-Up Air Horizontal DuctsContaminated Air Air for Combustion Flammable ItemsGas Valve Outlet View Venting Venting Atmospheric Multiple HeatersNine Rules for Good Vents SBN Tank Type Commercial GAS Water Heater Service Handbook SBN Tank Type Commercial GAS Water Heater Service Handbook Type B GAS Vent Multiple Gas Fired Tank-Type HeatersTechnical Dataventing Sequence Top ViewFront View of Water Heater SBN Tank Type Commercial GAS Water Heater Service Handbook HSI Integrated Ignition Control Board Lower Front View of SBN Water Heater HSIWiring Diagram ECOElectrical Sequence of SBN Water Heater Operation PRE-SERVICE Checklist Conditions Water Heater Control Ignition Control BoardFlash Codes of Diagnostic Indicator Test 2 Polarity CheckTest 2 Polarity Check Test 3 Continuity Check High Limit ECOIs indicated Test 4 Upper Temperature Probe Continuity CheckTest 3 Continuity Check of High Limit ECO Is not presentTest 5 Calling for Heat no Inducer Operation Water Heater ControlCheck to Inducer Test on Ignition Board 4 Pin Receptacle E4 Test 6 Inducer ON-NO Ignition VAC Check of Blower Prover/Low Gas Pressure CircuitVoltage is not present between E4, Pin Test 8 Igniter Heats no Main Burner Test of Igniter and gas valve circuitTest 9 Igniter Heats no Main Burner Continuity Check Of Gas Valve CoilTest 10 Main Burner Ignition for Less than 5 Seconds Flame Prover Circuit CheckTest 11 Water Heater Shutting OFF below Setting If… ThenDisplay Lights on Integrated Heater Control ECO SBN Tank Type Commercial GAS Water Heater Service Handbook Technical Training Department 120 154 180 199 200A 250A 275A 310A 366A 400A General Questions and Answers SBN Tank Type Commercial GAS Water Heater Service Handbook Draft Proving Pressure Switch Table