SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
LED INDICATORS ON HOT SURFACE IGNITION (HSI)
USING FLASHING RED LED ON HSI (HOT SURFACE IGNITION)
| LED STATUS | INDICATION | ACTION TO BE TAKEN |
|
|
|
|
| 7 Flashes | Flame sensor reads a | Verify that the main |
|
| low flame signal for | burner flame is in contact |
|
| more than 4.25 sec. | with the flame. |
|
|
| Check wiring and |
|
|
| connection to HSI |
|
|
| assembly. |
|
|
| Clean the flame sensor |
|
|
| rod of soot or metal |
|
|
| flakes. |
| 8 Flashes | No ignition sensed | Check igniter for lack of |
|
|
| voltage, cracks, or lose |
|
|
| connection. |
|
|
| at 77° F (25° C) is “good”] |
|
|
| Check ground |
|
|
| connection. |
|
|
|
|
| Continuous | Continuous flame | Check that the gas valve |
| Flash | sensed for more than 5 | is not failing to close at |
|
| seconds without gas | the end of a heating |
|
| valve being energized | cycle. |
|
|
|
|
| Continuous | Internal control board | Replace ignition control |
| ON | failure. | board. |
|
|
|
|
Technical Training Department | 39 | ©2003 |
Ashland City, Tennessee