State Industries STC-074 specifications SBN Tank Type Commercial GAS Water Heater Service Handbook

Page 40

SBN TANK TYPE COMMERCIAL GAS WATER HEATER

SERVICE HANDBOOK

LED INDICATORS ON HOT SURFACE IGNITION (HSI)

USING FLASHING RED LED ON HSI (HOT SURFACE IGNITION)

 

LED STATUS

INDICATION

ACTION TO BE TAKEN

 

 

 

 

 

7 Flashes

Flame sensor reads a

Verify that the main

 

 

low flame signal for

burner flame is in contact

 

 

more than 4.25 sec.

with the flame.

 

 

 

Check wiring and

 

 

 

connection to HSI

 

 

 

assembly.

 

 

 

Clean the flame sensor

 

 

 

rod of soot or metal

 

 

 

flakes.

 

8 Flashes

No ignition sensed

Check igniter for lack of

 

 

 

voltage, cracks, or lose

 

 

 

connection. [11-20 Ohms

 

 

 

at 77° F (25° C) is “good”]

 

 

 

Check ground

 

 

 

connection.

 

 

 

 

 

Continuous

Continuous flame

Check that the gas valve

 

Flash

sensed for more than 5

is not failing to close at

 

 

seconds without gas

the end of a heating

 

 

valve being energized

cycle.

 

 

 

 

 

Continuous

Internal control board

Replace ignition control

 

ON

failure.

board.

 

 

 

 

Technical Training Department

39

©2003

Ashland City, Tennessee

Image 40
Contents Service Handbook Table of Contents SBN Service Handbook Introduction Qualifications Custom Commercial Storage Tank Model Number Break DownInstallation Considerations Top and Front Views of Minimum Clearances To CombustiblesExterior Clearance Required Exterior ClearancesComb AIR Make-Up Air Direct Communication Not Direct Vent Make-Up Air Vertical Ducts Make-Up Air Horizontal DuctsContaminated Air Air for Combustion Flammable ItemsGas Valve Outlet View Venting Venting Atmospheric Multiple HeatersNine Rules for Good Vents SBN Tank Type Commercial GAS Water Heater Service Handbook SBN Tank Type Commercial GAS Water Heater Service Handbook Type B GAS Vent Multiple Gas Fired Tank-Type HeatersTechnical Dataventing Sequence Top ViewFront View of Water Heater SBN Tank Type Commercial GAS Water Heater Service Handbook HSI Integrated Ignition Control Board Lower Front View of SBN Water Heater HSIWiring Diagram ECOElectrical Sequence of SBN Water Heater Operation PRE-SERVICE Checklist Conditions Water Heater Control Ignition Control BoardFlash Codes of Diagnostic Indicator Test 2 Polarity CheckTest 2 Polarity Check Test 3 Continuity Check High Limit ECOTest 4 Upper Temperature Probe Continuity Check Test 3 Continuity Check of High Limit ECOIs indicated Is not presentWater Heater Control Test 5 Calling for Heat no Inducer OperationCheck to Inducer Test on Ignition Board 4 Pin Receptacle E4 Test 6 Inducer ON-NO Ignition VAC Check of Blower Prover/Low Gas Pressure CircuitVoltage is not present between E4, Pin Test 8 Igniter Heats no Main Burner Test of Igniter and gas valve circuitTest 9 Igniter Heats no Main Burner Continuity Check Of Gas Valve CoilTest 10 Main Burner Ignition for Less than 5 Seconds Flame Prover Circuit CheckTest 11 Water Heater Shutting OFF below Setting If… ThenDisplay Lights on Integrated Heater Control ECO SBN Tank Type Commercial GAS Water Heater Service Handbook Technical Training Department 120 154 180 199 200A 250A 275A 310A 366A 400A General Questions and Answers SBN Tank Type Commercial GAS Water Heater Service Handbook Draft Proving Pressure Switch Table