Cornelius 10, 000 installation manual Wiring Diagram LOW-VOLTAGE System

Page 40

35

30-9340-001

REVISION B

MODEL NUMBERS: 416593 496593

300381000

FIGURE 13. WIRING DIAGRAM (LOW-VOLTAGE SYSTEM)

Image 40
Contents AURORAR10,000 Cooling Unit This Document Contains Important InformationTable of Contents Table of Contents cont’d Table of Contents cont’d LOOSE-SHIPPED Parts General Description Cooling Unit DescriptionDesign Data Cooling Unit Model NumbersSystem Theory of Operation Remote Condenser Coil and FAN ASS’Y Data P/NFlow Diagram Typical Installation Unpacking and Inspection Identification of LOOSE-SHIPPED PartsSelecting Location Cooling UnitRemote Condenser Coil and FAN ASS’Y if Applicable Installing Cooling UnitPlacing Cooling Unit in Location Connecting Electrical Power Circuit to Cooling Unit 24VAC Power TransformerCooling Unit factory warranty Connecting Plain Water Inlet Supply Line to Cooling Unit Connecting CO2 Inlet Supply Line to Cooling UnitPlacing Cooling Unit in Operating Position Cooling Unit Space RequiredPreparing Cooling Unit for Operation OperationStarting Carbonated Water Circulating Pump Starting Cooling Unit Refrigeration SystemActivating Syrup Systems Dispensing Station Adjustments Installing Line Identification LabelAdjusting Water Flow Rate Leak Check and Insulating Cooling Unit Outlet LinesThis page Left Blank Intentionally Cooling Unit Refrigeration Power Switch Cooling Unit Carbonator Motor SwitchCooling Unit Circulating Motor Switch Operating ControlsAdjustments Cleaning and Sanitizing Cooling Unit MaintenanceCleaning CO2 GAS Check Valves Preparing Cooling Unit for SHIPPING, STORING, or Relocating Periodic InspectionCleaning Condenser Coil Periodic CleaningChecking ICE Water Bath Changing ICE Water Bath FAN Assembly Item 4 300381000 Carbonator Liquid Level Control Switches Carbonated Water Circulating Pump Motor Lubrication Primary CO2 RegulatorSecondary CO2 Regulators Index Part NameDaily Cleaning of Unit Adjusting Carbonators Tanks Liquid LevelsWater Flow Rate Wash Syrup Systems Sanitizing POST-MIX Syrup SystemsFlush Syrup Systems Sanitize Syrup Systems Water Flush Syrup SystemsPurge Water OUT of Syrup Systems Restore Operation Cleaning CO2 System GAS Check Valves Connecting External Carbonator to Cooling UnitSyrup Flavor Change Carbonators CO2 Inlet Lines CO2 GAS Check Valve300381000 300381000 Wiring Diagram LOW-VOLTAGE System Model Number Wiring Diagram HIGH-VOLTAGE System This page Left Blank Intentionally Dispensed Drink TOO WATER-TO-SYRUP ‘RATIO’LOW or TOO High Dispensed Product Carbonation TOO LOWComes OUT Dispensing Valve Clear But Foams in CUP Only Carbonated Water aOnly Carbonated Water Dispensed CONT’DOnly Syrup Dispensed Carbonator MotorsOperate Refrigeration Power Erratic CyclingCarbonator Water Pump MotorTemperature Sensing Operate CONT’DRefrigeration System Device and HIGH-PRESSUREBank CONT’D Refrigeration Flow Diagram Commpressor OperatesContinuousls but does Not Form Sufficient ICEWarranty Page One Cornelius Place Anoka, Minnesota 612 800
Related manuals
Manual 42 pages 12.14 Kb

000, 10 specifications

Cornelius 10,000 PLUS is a pioneering innovation in the beverage dispensing industry, designed to cater to the evolving needs of commercial establishments. This advanced system combines state-of-the-art technology with user-friendly features, making it a standout choice for restaurants, cafes, and bars aiming to enhance their beverage service.

One of the main features of the Cornelius 10,000 PLUS is its impressive capacity. With the ability to dispense a wide variety of beverages, including soft drinks, cocktails, and craft beers, the system supports a large volume of service, perfect for high-demand environments. The modular design allows for easy expansion, enabling businesses to add additional flavors or beverages as needed without major overhauls.

The technology behind the Cornelius 10,000 PLUS is equally impressive. It utilizes advanced cooling technology to ensure that beverages are served at the optimal temperature, enhancing the customer experience. The integrated touchless dispensing mechanism minimizes waste and ensures a hygienic experience, addressing growing concerns about cleanliness in food service environments. This technology also improves speed, allowing staff to serve customers more efficiently.

Another key characteristic of the Cornelius 10,000 PLUS is its digital integration capabilities. The system can be connected to a central management platform that tracks sales, inventory levels, and maintenance needs in real-time. This allows operators to optimize their beverage offerings based on customer preferences and reduces downtime through proactive maintenance alerts.

In addition to its performance features, the Cornelius 10,000 PLUS is designed with sustainability in mind. The system employs energy-efficient practices, reducing its environmental footprint while lowering operational costs. The materials used in construction are durable yet eco-friendly, ensuring longevity and less waste.

Overall, the Cornelius 10,000 PLUS stands out as an essential tool for any business looking to elevate its beverage service. With its combination of high capacity, cutting-edge technology, and sustainability features, it not only meets the demands of today’s fast-paced service environments but also positions establishments for future growth and success.