Access a Configured Network Management Card

Overview

After the Network Management Card is running on your network, you can access the configured Network Management Card through the following interfaces:

Web interface (HTTP or HTTPS protocol)

Telnet or Secure SHell (SSH)

SNMP

FTP or Secure CoPy (SCP) to upgrade firmware

Modbus

For more information on the interfaces, see the User’s Guide.

Web interface

Use Microsoft Internet Explorer® (IE) 5.5 and higher (on Windows operating systems only), Mozilla- based browsers that support Firefox 1.x (on all operating systems), or Netscape® 7.x and higher (on all operating systems) to access the Web interface of the cooling unit. Other commonly available browsers also may work but have not been fully tested by APC.

You can use either of the following protocols when you use the Web interface:

The HTTP protocol (enabled by default), which provides authentication by user name and password but no encryption.

The HTTPS protocol, which provides extra security through Secure Sockets Layer (SSL); encrypts user names, passwords, and data being transmitted; and authenticates the Network Management Card by means of digital certificates.

To access the Web interface and configure the security of your device on the network:

1.Address the Network Management Card by its IP address or DNS name (if configured).

2.Enter the user name and password (by default, apc and apc for an Administrator).

3.To enable or disable the HTTP or HTTPS protocols, use the Network menu on the Administration tab. Select the access option under the Web heading on the navigation menu.

For more information on selecting and configuring network security, see the Security Handbook, available on the Utility CD or from the APC Web site, www.apc.com.

InRow RD 10 kW Air Cooled Operation and Maintenance

37

Image 45
Contents Operation and Maintenance 동봉된 CD 안에 한국어 매뉴얼이 있습니다 American Power Conversion Legal Disclaimer Page Contents Cooling Group Configuration Network Management Card Page Symbols used in this manual Cross-reference symbol used in this manualOverview Safety Inspection Checklists Initial inspection checklistEnsure that Electrical inspection checklist Ensure that Mechanical inspection checklistStart-up inspection checklist User interface inspection checklistFinal inspection checklist While the cooling unit is operating, ensure thatCalculating R410A charge Charging With RefrigerantInRow RD 10 kW Air Cooled Operation and Maintenance Charging the equipment Compressor Oil Charge Oil charging procedureInRow RD 10 kW Air Cooled Operation and Maintenance Display Interface OperationScrolling status screens Using the Display InterfaceStatus Screen Name Status Information Displayed Main menu screensNavigating the sub-menus Navigating the main menuUsing the Path statement Password entryStart the cooling unit General Configuration Cooling unit configurationStop the cooling unit Configure the cooling group Cooling Group ConfigurationContacts View the state of input and output contactsIdentify the cooling unit Configure ModbusSetpoints Control the EnvironmentPID settings Loop Behavior PID Tuning Correction Tune the PID loopControl Method Proportional Integral Derivative Service intervals Run hoursThresholds Date and time Password and time-outDisplay units Adjust display settingsConfigure network Network ConfigurationCooling unit status View Status ReadingsAbout the cooling unit Cooling group statusEvent Log View the event logClear the event log View active alarms Respond to AlarmsClear active alarms Alarm messages and suggested actionsThreshlds screen Configure Unit Discrete I/O screen. See page 17 for more Quick Configuration TCP/IP configuration methodsOverview APC Device IP Configuration Wizard Bootp & Dhcp configurationIni file utility NetworkTCP/IPBoot ModeDHCP onlyAdvancedDHCP Cookie Is Remote access to the control console Local access to the control consoleChoose Network from the Control Console menu Control consoleWeb interface Access a Configured Network Management CardTelnet and SSH Modbus Simple Network Management Protocol SnmpRecover From a Lost Password Monthly Preventive Maintenance CleanlinessEnvironment Electrical MechanicalFunctional tests Semi-Annual Preventive MaintenanceProblem Possible Cause Corrective Action TroubleshootingCorrective Action Problem Possible CausePage Page 990-3212A-001 11/2009 APC Worldwide Customer Support