Bradford-White Corp MITW -12 / -15, MITW -10 manual Check all safety devices to make sure they

Page 11

TTW1 Universal Service

Replacement Blower

MITW -10 Series

Step 12. Find the rubber vent adapter kit, P/N 239-46263-00, provided with the blower kit. Install the 2” vent adapter on the exhaust side of the universal blower. Discard the vent terminal included with the vent adapter kit.

Note: In order to prevent condensate from draining back into the blower (vertical or horizontal runs), an optional condensate kit is available as a service part (Condensate kit, P/N 239-45875-00).

Step 13. If it has not already been done, remove the old vent adapter from the existing vent pipe.

Step 14. If necessary, re-route the vent pipe such that it can be properly seated in the top portion of the vent adapter.

Step 15. Be sure that both clamps on the vent adapter are firmly tightened, securing the blower, vent adapter, and vent pipe together.

Be sure that vent pipe is properly seated in the top side of vent adapter.

Rubber vent

adapter

Adequately tighten both

clamps on the vent adapter.

Step 16. Double-check all vent connections.

Step 17. Restore electrical power to the water heater.

Plug power cord back into outlet.

Warning:

Check all safety devices to make sure they

 

are working properly. Improper water heater

 

operation could occur if these devices are not

 

functioning properly.

Page 11

Image 11
Contents Instructions for Model Numbers Reference Kit Components Tools Required Bradford White TTW1 Universal Service Replacement Blower Step Remove the screws, qty , that secure Inside the access compartment, follow Just below the crimp connector, cut Plug both the blower Check all safety devices to make sure they Unplug the water heater from wall outlet Mitw -12 / -15 Series Place template on top of water heater in correct orientation TTW1 Universal Service Replacement Blower Secure Cover Screws Blower screws TTW1 Universal Service Replacement Blower Do not over tighten 2 screws attaching Tighten 2 screws on junction Box to secure cover Operation could occur if these devices are not M1TW60T*FCX TTW1 Universal Service Replacement Blower TTW1 Universal Service Replacement Blower Secure Cover screws Boot back Place Secure 3 blower screws Step If the new adapter is used, remove the old