TTW1 Universal Service
Replacement Blower
MITW
Note: This set of instructions is for the following model numbers: MITW40L*EN12,
MITW40L*BN12, MITW40L*CX12, MITW50L*EN12, MITW50L*BN12,MITW50L*CX12, MITW40L*EN15, MITW40L*BN15, MITW40L*CX15, MITW50L*EN15, MITW50L*BN15, and MITW50L*CX15.
Note: The following parts are required to convert the model numbers shown above: Template, Flue Restrictor, Screws, Wire Harness
Step 1. On the water heater’s gas control, turn the power switch to the “Off” position.
Turn switch on gas
valve to “Off” position.
Step 2. Unplug the water heater from wall outlet.
Remove power
cord from
outlet.
Unscrew both clamps that
hold the adapter to the blower and vent pipe.
Step 3. Disconnect the vent pipe and adapter that are connected to the outlet of the blower.