TTW1 Universal Service

Replacement Blower

MITW -12 / -15 Series

Note: This set of instructions is for the following model numbers: MITW40L*EN12,

MITW40L*BN12, MITW40L*CX12, MITW50L*EN12, MITW50L*BN12,MITW50L*CX12, MITW40L*EN15, MITW40L*BN15, MITW40L*CX15, MITW50L*EN15, MITW50L*BN15, and MITW50L*CX15.

Note: The following parts are required to convert the model numbers shown above: Template, Flue Restrictor, Screws, Wire Harness MITW-12/15Series, Universal Blower, Transformer, Junction Box & its Cover, Wire Nuts, and 2" Exhaust Adapter / Vent Terminal Kit. Please refer to the Kit Components page (Page 3) for a picture of each item.

Step 1. On the water heater’s gas control, turn the power switch to the “Off” position.

Turn switch on gas

valve to “Off” position.

Step 2. Unplug the water heater from wall outlet.

Remove power

cord from

outlet.

Unscrew both clamps that

hold the adapter to the blower and vent pipe.

Step 3. Disconnect the vent pipe and adapter that are connected to the outlet of the blower.

Page 12

Image 12
Contents Instructions for Model Numbers Reference Kit Components Tools Required Bradford White TTW1 Universal Service Replacement Blower Step Remove the screws, qty , that secure Inside the access compartment, follow Just below the crimp connector, cut Plug both the blower Check all safety devices to make sure they Unplug the water heater from wall outlet Mitw -12 / -15 Series Place template on top of water heater in correct orientation TTW1 Universal Service Replacement Blower Secure Cover Screws Blower screws TTW1 Universal Service Replacement Blower Do not over tighten 2 screws attaching Tighten 2 screws on junction Box to secure cover Operation could occur if these devices are not M1TW60T*FCX TTW1 Universal Service Replacement Blower TTW1 Universal Service Replacement Blower Secure Cover screws Boot back Place Secure 3 blower screws Step If the new adapter is used, remove the old