Bradford-White Corp MITW -12 / -15, MITW -10 manual TTW1 Universal Service Replacement Blower

Page 15
Power cord
Power inlet
connector

TTW1 Universal Service

Replacement Blower

MITW -12 / -15 Series

Step 9.

b.) Inside the access compartment, follow the black wire from the power cord until you reach the flag terminal attached to the end of the wire. Disconnect black wire from the back of the power inlet connector.

c.) Just below the crimp connector, cut the (3) white (neutral) wires. Remove the white power cord lead from the bundle. Then, strip the ends of the (2) remaining white wires and connect them using a wire nut, included with the kit, P/N 239-47281-00, and tuck the wires back into the lower portion of the access compartment.

d.) Just below the crimp connector, cut the

(3)green (ground) wires. Remove the green power cord lead from the bundle. Then, strip the ends of the (2) remaining green wires and connect them using a wire nut, included with the kit, P/N 239-47281-00, and tuck the wires back into the lower portion of the access compartment.

Warning:

Make sure that each wire nut is securely

 

 

tightened and that all wires are making

 

 

good connection or improper water heater

 

 

operation will occur.

 

 

 

 

 

 

e.) Remove the power cord from the

 

 

blower housing and discard.

 

 

 

 

 

 

Push in both sides of

 

 

the bushing with pliers

 

 

to remove.

 

Black wire

Remove black

wire’s flag terminal

Cut just below these crimp connectors. Then, remove (1) white and (1) green wire from bundles. Trace wires back to power cord.

Connect (2) white wires Power cord and (2) green wires, each

with their own wire nut.

Squeeze bushing to remove power cord from blower.

Page 15

Image 15
Contents Instructions for Model Numbers Reference Kit Components Tools Required Bradford White TTW1 Universal Service Replacement Blower Step Remove the screws, qty , that secure Inside the access compartment, follow Just below the crimp connector, cut Plug both the blower Check all safety devices to make sure they Unplug the water heater from wall outlet Mitw -12 / -15 Series Place template on top of water heater in correct orientation TTW1 Universal Service Replacement Blower Secure Cover Screws Blower screws TTW1 Universal Service Replacement Blower Do not over tighten 2 screws attaching Tighten 2 screws on junction Box to secure cover Operation could occur if these devices are not M1TW60T*FCX TTW1 Universal Service Replacement Blower TTW1 Universal Service Replacement Blower Secure Cover screws Boot back Place Secure 3 blower screws Step If the new adapter is used, remove the old